Electrical Calculations for Code Exams
The calculations Canadian electrical licensing exams test: demand loads under Section 8, conductor sizing, voltage drop, box fill and transformer and motor sizing.
MELC-102 12 lessons · 5 h 24 min ▶ Video lessons coming soon
Offered by HSM University · Master Electrician and Contractor Exam Prep (Canada)
What you'll learn
- Apply Ohm's law, the power equations, efficiency and power factor to find currents, resistances, power and energy, and check answers for units, size and direction.
- Calculate voltages and line currents in 120/240 V single-phase and 120/208 V and 347/600 V three-phase systems, including balanced loads and wye neutral currents.
- Calculate the load for a single dwelling under Rule 8-200, including living area, heating, air conditioning, the range, full-value loads, other large loads and the minimum.
- Calculate per-unit loads and combined service loads for apartments, row housing and houses with secondary suites using the stepped demand factors of Rule 8-202.
- Apply the floor-area method of Rules 8-204 to 8-210 and Table 14 for schools, hospitals, hotels and other occupancies, and use Rule 8-106 for recorded demand and non-coincident loads.
- Select conductors from the Section 4 ampacity tables, applying ambient and bundling corrections, termination temperature limits and the continuous-load rule.
- Calculate single-phase and three-phase voltage drop, size conductors for long runs within the limits of Rule 8-102, and use the Appendix D tables.
- Check box fill under Rule 12-3034 and conduit fill with the conductor and raceway area tables and the fill limits.
- Choose transformer ratings, calculate rated currents, and apply Rules 26-254 and 26-256 for overcurrent protection and conductors, including secondary fault current.
- Size motor branch circuit conductors, feeders, short-circuit protection, overload protection and disconnecting means under Section 28.
- Work complete service and feeder sizing problems from demand load to equipment ratings, including managed EV loads and neutral sizing.
- Solve mixed calculation questions under exam conditions using a consistent layout, without reproducing Code tables, by looking up every value in the 2024 CE Code.
Course content
12 lessons · 5 h 24 min total · final exam
- 1 Exam math refresher: Ohm's law and power 26 min · quiz
- 2 Single-phase and three-phase calculations 27 min · quiz
- 3 Section 8 demand loads for dwelling units 25 min · quiz
- 4 Demand loads for apartments and row housing 24 min · quiz
- 5 Demand loads for schools, hospitals and other buildings 25 min · quiz
- 6 Ampacity tables and correction factors 26 min · quiz
- 7 Voltage drop calculations 24 min · quiz
- 8 Box fill and conduit fill 23 min · quiz
- 9 Transformer sizing and protection 27 min · quiz
- 10 Motor branch circuit calculations 31 min · quiz
- 11 Service and feeder sizing worked examples 27 min · quiz
- 12 Mixed calculation practice set 39 min · quiz
- E Final exam 20 questions