APP-220 · Lesson 5 of 12 · 23 min
Motors, belts and direct drives
▶ Video coming soon A video version of this lesson is on the way.
Harriet finished the October 28 laundry night with the motors. On the bench she set out four: a two-speed PSC motor from an old belt-drive top-loader, a brushed universal motor from a 2010 front-loader, the stator and rotor of a direct-drive front-loader, and the motor and inverter board from a 2018 HE top-loader. "Four motors, four ways of turning a drum," she said. "You learned how these work as electrical parts in APP-120. Tonight is about how a washer uses each one, what goes wrong with them, and how you tell a motor fault from a fault somewhere else."
This lesson covers the motors and drive trains of washers: induction motors with capacitors, universal motors with brushes, inverter-driven induction motors, and brushless direct-drive motors. It covers belts and pulleys, speed sensing and the safe testing of each motor. It also covers drive faults that are not motor faults at all. APP-120 covered motor principles and capacitor testing; APP-320 goes much further into inverter and brushless motor electronics.
PSC induction motors
Older top-loaders, both belt-drive and direct-drive, use a permanent split capacitor (PSC) induction motor or a split-phase motor. These run at a fixed speed set by the supply frequency and the number of poles, typically about 1,725 rpm for a four-pole motor at 60 Hz, and many have two speeds selected by different windings. The direction is reversed by swapping which winding the capacitor feeds, which is how a direct-drive washer switches between agitation and spin. The motor has a thermal overload, and some have a centrifugal start switch.
Testing a PSC motor means reading its windings against the tech sheet, testing its capacitor as APP-120 described, and checking for a winding shorted to the frame. A motor that hums without turning has an open start winding, a failed capacitor or a seized load. Disconnect the load, the coupling or belt, and see whether the motor spins freely by hand and starts on its own. If it does, the problem is in the gearcase or transmission, not the motor. A motor that trips its overload after a few minutes may be overloaded by a dragging brake, a tight transmission or an overloaded basket.
Universal motors
Many front-loaders of the 2000s and early 2010s, and some current compact models, use a universal motor: a brushed series motor whose field and armature carry the same current, fed through carbon brushes that press on a commutator. A universal motor's speed changes with the voltage and load, so the board controls it with a triac, chopping the supply to set the speed, and reads the actual speed from a small tachometer generator on the end of the motor shaft. The board can therefore run the motor slowly in either direction for washing, by reversing the field connections with relays, and fast for spinning.
Universal motors wear their brushes. As the brushes shorten, the spring pressure on them drops, they arc against the commutator, the motor loses power, and the customer reports weak spins, a burning smell, sparks visible through the motor's vents, or a washer that stops with a motor or tach code. Brushes are replaced in pairs, and the commutator is inspected for burned or raised segments. The tachometer coil, with a resistance typically in the range of about 50 to 200 Ω, can open or come loose from its magnet; then the board cannot see the motor turning and stops it with a code even though the motor itself is good.
Worked problem
Worn motor brushes
On Wednesday, September 30, Dee went to Cormac Penhaligon's 2012 front-load washer in Mount Hope. It washed normally but its spins were weak and it smelled of hot carbon. With the motor out, the brushes measured 7 mm and 8 mm long. The tech sheet gave a new brush length of 18 mm and a replacement limit of 10 mm. How much of each brush was used, and should they be replaced?
Show solution
- Brush 1: 18 − 7 = 11 mm used, 7 mm left, below the 10 mm limit.
- Brush 2: 18 − 8 = 10 mm used, 8 mm left, below the limit.
- Both are worn past the limit, and they are replaced as a pair.
- The commutator showed even dark colouring with no raised or burned bars, so it could be reused after cleaning.
Answer: Both brushes were below the replacement limit. Dee fitted a new brush pair, and a test spin reached the full 1,200 rpm with no sparking or smell.
Inverter-driven induction motors
Some washers, especially earlier HE front-loaders, use a three-phase induction motor driven by an inverter board, often called the motor control unit. The inverter rectifies the household 120 V AC supply to direct current, then switches that direct current to make three-phase power at whatever frequency and voltage the washer needs, so the motor can turn slowly for washing and very fast for spinning, in either direction. Because the inverter sets the frequency, the motor's speed is controlled closely, and the motor itself has no brushes to wear.
The motor has three windings of equal resistance, which can be compared at the motor connector: three readings within a fraction of an ohm of each other are normal, one open or very different reading means a failed winding. The inverter board is a more common failure than the motor itself, often after a power surge, a water leak onto the board or a seized drum bearing that overloaded it. On many models the main board and the inverter communicate over a data line, and a communication error code may point to either board or to the harness between them.
Brushless direct-drive motors
Most current front-loaders, and many HE top-loaders, use a brushless DC motor mounted directly on the drum shaft or the gearcase. The stator, a ring of wound poles, is bolted to the back of the tub; the rotor, a ring of permanent magnets, is bolted to the shaft and turns around the stator. There is no belt, no pulley and no brushes. An inverter board switches the three stator windings in sequence to pull the rotor around, and uses hall-effect sensors, or on some designs the voltages in the windings themselves, to know where the rotor is. These motors are quiet, efficient and can turn the drum at any speed from a slow rock to a fast spin.
Direct-drive motors fail less often than belts and brushes, but they do fail. The rotor can come loose on its shaft if its centre bolt loosens, and then it clunks and rubs. Water from a tub seal leak can corrode the stator or the hall sensor. A stator winding can open or short. As with an inverter-driven induction motor, the three windings should read nearly equal resistance, often a few ohms to a few tens of ohms each depending on the model, and none should read continuity to the stator core. A hall sensor fault gives a motor code and a drum that jerks or does not start. APP-320 covers hall sensors and inverter boards in detail.
The inverter boards that drive both these motor types store a dangerous charge. The rectified supply on the board's capacitors can be roughly 170 V DC, and on designs that double the voltage, over 300 V DC, and it can remain for a minute or more after the washer is unplugged. Unplug the washer, wait the time the tech sheet gives, then verify with a meter across the capacitor or the test points before touching the board or its connectors, exactly as with the microwave capacitor in APP-110.
| Motor type | Where used | Speed control | Typical faults |
|---|---|---|---|
| PSC or split-phase induction | Older top-loaders | Fixed speeds; direction by capacitor switching | Open winding, failed capacitor, overload trips |
| Universal (brushed) | Front-loaders of the 2000s and 2010s, some compacts | Triac on the board; tachometer feedback | Worn brushes, burned commutator, open tach coil |
| Three-phase induction with inverter | Earlier HE front-loaders | Inverter sets frequency and voltage | Inverter board failure, open winding |
| Brushless direct drive | Most current front-loaders, many HE top-loaders | Inverter switches windings; hall sensors or back-voltage | Loose rotor, hall sensor failure, stator corrosion, inverter failure |
Belts and pulleys
Belt-driven front-loaders use a multi-rib belt, sometimes called a poly-V or micro-V belt, from a small pulley on the motor to a large pulley on the drum shaft. Many use a stretch belt with no tensioner: the belt is fitted under tension by rolling it onto the pulley while turning the drum by hand. The belt ratio is large, often around 10 to 1 or more, so a motor turning at over 10,000 rpm drives the drum at 1,000 rpm or more in spin. A belt that is worn, glazed or cracked slips, especially with a heavy load; a belt that has come off is often a symptom of a worn drum bearing letting the pulley wobble, a loose motor mount or a loose pulley bolt, rather than a belt fault in itself.
Worked problem
Belt ratio and motor speed
A belt-drive front-loader has a 30 mm motor pulley and a 320 mm drum pulley. What motor speed gives a drum speed of 1,200 rpm, and what drum speed does the motor's tachometer imply when the board reads 9,000 rpm?
Show solution
- Ratio: 320 ÷ 30 = 10.67 to 1.
- Motor speed for 1,200 rpm at the drum: 1,200 × 10.67 = 12,800 rpm.
- Drum speed when the motor turns 9,000 rpm: 9,000 ÷ 10.67 = 844 rpm.
Answer: The motor must turn more than 10 times as fast as the drum. If the drum is clearly turning slower than the tachometer implies, the belt is slipping.
When replacing a belt, inspect the drum pulley for cracks, check the pulley bolt torque and the motor mounts, and turn the drum by hand to feel for bearing roughness. Fitting a new belt to a washer whose bearing is failing only buys a few weeks.
Telling a motor fault from a load fault
A washer motor that will not turn the drum may be at fault, or it may be fighting a load it cannot move. Before condemning the motor, unplug the washer and turn the drum or basket by hand. It should turn smoothly with only the drag of the belt and bearings. A drum that will not turn may have a sock jammed between drum and tub, a seized bearing or a broken spider; a basket that will not turn on a top-loader may have a seized gearcase. Then check whether the motor is being commanded: in service mode, run the motor and read the voltage or the inverter's output, and read the motor or tachometer code the board reports. A motor with power, free load and good windings that still will not turn points to the board or inverter; a motor with no power points to the control or its wiring.
A drum that turns but makes a regular thump on each revolution may have a loose rotor on a direct drive, a loose pulley on a belt drive or an object caught between the drum and tub. Underwire from bras is the classic example: it works out through the drum holes and rattles or scrapes on every turn, and can puncture the tub or block the drain pump. Removing the heater from the bottom of the tub on many front-loaders gives access to fish out such objects.
Insulation testing and motor heat
A motor winding can read the right resistance and still be faulty if its insulation has broken down to the frame. On a cold, dry motor, a good winding reads open to the frame on an ordinary meter, and on an insulation tester, where the technician has one and the maker's procedure allows it, it reads many megohms. A low reading, often appearing only when the motor is damp, can trip a GFCI or give a tingle from the cabinet, as APP-110's two-prong receptacle call showed. Water leaking onto a motor from a failed tub seal or pump is a common cause, so a motor that reads low to the frame should prompt a look for a leak above it.
Motors also protect themselves from heat. Most have a thermal protector that opens if the windings overheat, then resets when they cool. A washer motor that stops partway through a heavy load and starts again after half an hour has probably tripped its protector, and the cause is usually an overload: a drum dragging on a failing bearing, an overloaded basket or a belt that is too tight. Replacing the motor without finding the overload leads to the same complaint on the new one.
Common mistakes
MistakeCondemning a universal motor without checking its brushes.
InsteadMeasure brush length against the tech sheet's limit and replace in pairs.
MistakeTouching an inverter board straight after unplugging the washer.
InsteadWait the stated time and verify the capacitors are discharged with a meter.
MistakeFitting a new belt without finding why the old one came off.
InsteadCheck the bearing, pulley bolt and motor mounts.
MistakeReplacing a motor that cannot turn a seized drum.
InsteadTurn the drum or basket by hand first.
MistakeIgnoring the tachometer or hall sensor.
InsteadA board that cannot see the motor turning will stop it with a code even if the motor is good.
Summary and key terms
- Older top-loaders use PSC or split-phase induction motors with fixed speeds; reverse rotation selects wash or spin.
- Universal motors are controlled by a triac with tachometer feedback; worn brushes are their commonest fault.
- Inverter-driven induction and brushless direct-drive motors have three windings that should read nearly equal.
- Direct-drive motors have no belt or brushes; loose rotors, hall sensors and corrosion are their typical faults.
- Inverter boards can hold roughly 170 to over 300 V DC after unplugging; wait and verify before touching.
- Front-load belts run at large ratios; a thrown belt often means a bearing, pulley or mount problem.
- Turn the drum by hand and check the command before blaming the motor.
- PSC motor
- A permanent split capacitor induction motor, with a run capacitor always in circuit.
- Universal motor
- A brushed series motor that runs on AC, used in many front-loaders with triac speed control.
- Carbon brush
- A block of carbon that carries current to a universal motor commutator and wears in use.
- Tachometer generator
- A small coil and magnet on a motor shaft that tells the board the motor speed.
- Inverter board
- A board that makes variable-frequency power to drive a motor at any speed.
- Brushless direct drive
- A motor whose magnet rotor is mounted on the drum shaft and whose windings are switched by an inverter.
- Hall-effect sensor
- A sensor that detects a magnet, used to tell an inverter where a brushless rotor is.
- Multi-rib belt
- A flat belt with several small V-ribs, used to drive many front-load drums.
Practice problems
Work each problem on paper first, then reveal the answer to check.
How does a universal-motor washer control its drum speed?
Show answer
The board chops the supply with a triac and reads speed from a tachometer.
What should three stator windings on a direct-drive motor read?
Show answer
Nearly equal resistance, with no continuity to the core.
Why must you wait before touching an inverter board?
Show answer
Its capacitors can hold a high DC charge after the washer is unplugged.
A belt keeps coming off a front-loader. What should you check besides the belt?
Show answer
The drum bearing, pulley bolt and motor mounts.
How do you rule out a seized load before condemning a motor?
Show answer
Unplug the washer and turn the drum or basket by hand.
Lesson quiz · 5 questions
Score 60% or more to complete this lesson.
Create a free account to save your progress, take quizzes and earn a certificate.