On Saturday, October 17, 2026, Lorne Fitzwilliam called in sick, and Pilar Quenneville took the day shift with Tamar Ellingsen and a relief operator, Okonkwo Demarest, who usually worked nights. Between 07:00 and noon Pilar took over the plant from Desmond Kirwan, issued a hot work permit to a welder from Fenella Thorncroft's crew repairing a handrail on the deaerator platform, took a call from the seniors' residence on the district loop complaining that one wing was cold, dealt with a cut hand when Okonkwo caught his knuckle on a valve handwheel, and kept the plant running through the morning load swing. At lunch Tamar asked her how she kept track of it all. "I don't do it all," Pilar said. "I decide what matters most right now, I give the rest to someone I trust, and I check that it got done. That's the job."
A fourth class certificate is the first step toward being in charge of a shift. This lesson covers what the law expects of the person in charge, shift turnover from the supervisor's side, setting priorities and delegating, supervising contractors and permit work, fatigue, emergencies, coaching trainees, communication with customers and management, and the shift engineer's role in safety.
Who may be in charge
In Ohio, ORC Chapter 4104 requires that boilers above the exempt sizes be operated by people holding the appropriate license: a high pressure boiler operator's license or a stationary steam engineer's license for a plant like Cantwell. The owner's staffing plan, agreed with the insurer, sets how many licensed people are on each shift and who is in charge. The chief engineer is responsible for the safe management, operation and maintenance of the plant, and for directing, supervising and training the shift engineers and operators.
At Cantwell, Grazyna Wolanski is the chief engineer, holding a stationary steam engineer's license, and the shift engineers, Lorne, Pilar and Desmond, hold licenses suited to the plant. When Tamar earns her high pressure boiler operator's license, she will be able to operate the boilers as part of a shift, but she will still work under a more experienced shift engineer while she builds toward the stationary steam engineer's license.
The person in charge of a shift also carries the employer's duties under the Occupational Safety and Health Act on that shift: to keep the workplace free of recognized hazards, to make sure workers follow the OSHA standards and the plant's procedures and use the protective equipment required, and to tell workers about the hazards they face. OSHA standards repeatedly require a competent person or qualified person for particular work, and the shift engineer is often the one who decides whether a task can go ahead.
Taking over the shift
Lesson 8 described turnover as a matter of records. For the person taking charge it is also a matter of judgment. Pilar's routine was the same every shift:
- Arrive early enough to read the log since her last shift, not just the last page.
- Hear the outgoing engineer's briefing face to face, with the shift report in hand, and ask questions until she understood every open item.
- Look at the control screens for alarms, shelved alarms, loops in manual and anything unusual in the trends.
- Walk the plant, or send someone she trusted to walk it, before the outgoing shift had gone home, so that anything found could be asked about.
- Sign the log to accept the shift only when satisfied.
Desmond's report that morning listed boiler 3 on standby, the turbine-driven feed pump tested and on standby, two shelved alarms with their reasons, the hot work permit requested for the deaerator platform, and a note that the seniors' residence had reported a slow warm-up the evening before. Because Pilar had read that note, the call from the residence at 08:40 did not surprise her.
Setting priorities
A shift rarely goes to plan. The person in charge sorts the work into what must be done now, what must be done this shift, and what can wait, and keeps revisiting the list as things change. The order of priority in almost every plant is the same:
- People: injuries, people in danger, anything that could hurt someone in the next few minutes.
- Plant safety: anything threatening the boilers or other equipment, such as low water, a fire, or a safety device out of service.
- Supply to customers: keeping steam and hot water on the mains, especially to vulnerable customers such as the seniors' residence.
- The environment: spills, emissions and discharges.
- Equipment protection and efficiency.
- Routine work: rounds, tests, housekeeping and paperwork, which must still be done but can move within the shift.
Okonkwo's cut hand came first. Pilar sent Tamar back to the control room while she gave first aid from the plant's kit, judged the cut minor, recorded it in the first aid log and the plant log, and found him a task that did not need gloves that gripped. The cold wing at the seniors' residence came next: she checked the loop supply temperature and differential pressure at the plant, found them normal, and called the residence's maintenance man, who found a stuck control valve on the wing's heat exchanger and freed it. The handrail repair could wait until the morning load swing was over.
Worked problem
Ranking risks on a shift
Pilar uses a simple matrix in which risk = likelihood × severity, each scored from 1 (low) to 5 (high). Rank these three items: a steam trap blowing in vault 6 (likelihood of harm 2, severity 2), the hot work on the deaerator platform near insulation that might hold oil (likelihood 3, severity 4), and a guard missing from a running condensate pump coupling (likelihood 3, severity 5).
Show solution
- Steam trap:
- \[2 \times 2 = 4\]
- Hot work near insulation:
- \[3 \times 4 = 12\]
- Missing guard on a running coupling:
- \[3 \times 5 = 15\]
Answer: The missing guard ranks highest: stop the pump, start the standby and fix the guard before anyone works near it. The hot work comes next, with a fire watch and a check of the insulation before the permit is issued. The trap goes on a work order. A matrix does not replace judgment, but it helps explain decisions to others.
Delegating and following up
No shift engineer can be everywhere. Delegating well means giving a task to someone who is competent to do it, explaining what is wanted, why, by when and what to report back, making sure they have what they need, and then following up. A task given without a check that it was done is a task that may not have been done.
Delegation also means knowing what not to delegate. Accepting the shift, authorizing permits, deciding to take a boiler off line, resetting a safety trip and dealing with an injury stay with the person in charge. A trainee like Tamar can be given real work, such as taking readings, starting a pump with supervision, or calling a customer back with information, but not the decisions that the law places on a certified engineer.
Good supervisors communicate in a way that leaves no doubt. Instructions are specific ("Start feed pump 2, check the discharge pressure is above 190 psi, then stop feed pump 1 and tell me"), and important ones are repeated back by the person receiving them. Radios are used with the same discipline: identify yourself and the person you are calling, keep it short, and confirm.
Contractors and permit work
Contractors are a fact of plant life: welders, insulators, burner technicians, chemical suppliers, electricians and controls specialists. The shift engineer is usually the person who lets them into the plant, authorizes their work and makes sure it is safe. That involves:
- Confirming who they are, what they are there to do and who arranged it.
- A site orientation covering emergency alarms, exits, muster point, hazards in the area, the plant's rules and who to call.
- Issuing the right permits: hot work, confined space entry, lockout, work at heights, excavation, or a general work permit, each with its precautions.
- Checking the work area before and after, including the fire watch after hot work.
- Recording contractors in the log, with their arrival and departure times.
The hot work permit for the deaerator platform required a check of the area for combustibles, a fire extinguisher at hand, a fire watch during the work and for at least 60 minutes afterwards, and a check that no insulation in the spark zone was oil-soaked. Pilar issued it at 11:30, after the morning swing, with Okonkwo as fire watch, and closed it out at 14:10 after her own inspection. Permits are covered in detail in PWR-110; the supervisor's duty is to make sure the conditions on the permit are actually in place, not just written down.
Fatigue and fitness for duty
Shift work is hard on the body. Cantwell's rotation of two 12-hour days, two 12-hour nights and four days off averages 42 hours a week, but the nights and the long shifts produce fatigue that slows reactions and judgment, especially in the early hours of the morning. Studies of industrial incidents repeatedly find fatigue among the causes.
Worked problem
Hours on the rotation
Cantwell's rotation is two days, two nights and four days off, with 12-hour shifts. What is the average working week?
Show solution
- Hours worked in one cycle:
- \[4 \times 12 = 48 \text{ h in 8 days}\]
- Scale to a week:
- \[48 \times \frac{7}{8} = 42 \text{ h a week}\]
Answer: An average of 42 hours a week. When someone calls in sick and others cover with overtime, the hours on a single stretch can rise quickly, and the person in charge should watch for it.
The person in charge watches for fatigue in others and in themselves: someone who has worked a double shift, someone who seems slow or confused, someone just back from illness. Plants set limits on consecutive hours and shifts. Fitness for duty also covers impairment from alcohol, drugs, including legal cannabis and prescription medications, and illness. A supervisor who believes a worker is not fit for safety-sensitive work must not let them do it, and follows the plant's policy for what happens next.
Lorne's sick call that morning was a sign of a healthy plant, not a problem. Coming to work sick, and making decisions in charge of a plant while unwell, is worse than calling in.
Emergencies
In an emergency the person in charge becomes the plant's incident commander until someone more senior arrives or emergency services take over. The plant's emergency response plan, practiced in drills like the October 14 exercise in PWR-110, sets out the roles. The common principles are:
- Protect people first: raise the alarm, evacuate if needed, account for everyone at the muster point.
- Make the plant safe: shut down or isolate what is causing the emergency, as far as can be done without putting anyone at risk.
- Call for help early: emergency services, the chief engineer, the utility, the gas company.
- Keep one person in charge, and make sure everyone knows who it is.
- Record times and actions as they happen, or have someone else record them.
After the emergency, the person in charge makes sure the scene is preserved for investigation where required, injured people are looked after, regulators are notified as required, and the log tells the full story.
Coaching trainees
Part of every certified engineer's job is to train the people who will replace them. Good coaching on shift has a pattern: explain what is about to happen and why, let the trainee watch, then let them do it under supervision, then let them do it with the supervisor nearby, and finally check their understanding by asking them to explain it. Questions like "What would you do if the drum level started falling now?" teach more than any lecture.
A supervisor also signs the trainee's experience record, and that signature means something: it says the trainee did the work and was competent at it. Pilar signed Tamar's record for the day with a note: "Assisted with shift turnover, customer call and hot work permit; took all rounds."
Communicating upward and outward
The shift engineer is the plant's face to its customers, contractors and owner outside office hours. Calls from customers are answered politely and recorded, with the time, the caller, the problem and what was done. Problems that may affect customers, such as a planned shutdown or a supply reduction, are reported to the chief engineer, who decides how customers are told.
Knowing when to call the chief engineer at home is part of judgment. Most plants have a list: any injury beyond first aid, any boiler taken off line unexpectedly, any safety device found defective, any reportable spill or regulatory contact, any loss of supply to customers, and anything the shift engineer is unsure about. Pilar called Grazyna at 09:15 to tell her about Lorne's absence, the cut hand and the residence complaint, and said she did not need her to come in. Grazyna agreed, and asked to be called if anything else came up.
Common mistakes
MistakeAccepting a shift without reading the log or walking the plant.
InsteadRead the log since your last shift, get a face-to-face briefing, check the screens and walk the plant before signing.
MistakeDoing everything yourself instead of delegating.
InsteadDelegate tasks to competent people with clear instructions, and follow up.
MistakeDelegating decisions the law places on the person in charge.
InsteadPermits, safety trips, taking boilers off line and accepting the shift stay with the certified engineer.
MistakeIssuing a permit without checking the conditions in the field.
InsteadInspect the area and confirm the precautions are in place before signing.
MistakeLetting a fatigued or impaired worker continue safety-sensitive work.
InsteadRemove them from the work and follow the plant's fitness for duty policy.
Summary and key terms
- ORC Chapter 4104 requires licensed operators for boilers above the exempt sizes; the staffing plan sets who is in charge.
- The shift engineer carries the employer's OSHA duties on the shift and often decides whether work can go ahead.
- Priorities run from people, through plant safety, customers and environment, to routine work.
- Delegate with clear, repeated-back instructions and follow up; keep legal decisions with the person in charge.
- Contractors get an orientation and the right permits, with conditions checked in the field.
- Watch for fatigue and impairment; in an emergency the person in charge leads until relieved.
- Shift engineer
- The certified engineer in charge of a plant during a shift, under the direction of the chief engineer.
- Competent person
- A person qualified by knowledge, training and experience to organize work and aware of its hazards.
- Repeat-back
- Confirming an instruction by repeating it to the person who gave it.
- Fitness for duty
- A worker's physical and mental ability to do safety-sensitive work without impairment.
- Incident commander
- The person in charge of the response to an emergency until relieved.
Practice problems
Work each problem on paper first, then reveal the answer to check.
A rotation has three 12-hour shifts followed by three days off. What is the average weekly hours?
Show answer
36 h in 6 days; 36 × 7 ÷ 6 = 42 h a week.
Rank by risk score: a leaking flange (likelihood 3, severity 2) and an open floor grating (likelihood 2, severity 4).
Show answer
Leaking flange 6; open grating 8. Deal with the grating first.
A contractor arrives to replace insulation on a steam line. What must happen before work starts?