PWR-220 · Lesson 10 of 12 · 21 min

The ASME Boiler and Pressure Vessel Code and National Board inspection code

▶ Video coming soon A video version of this lesson is on the way.

On a shelf behind Grazyna Wolanski's desk at Cantwell sit a row of binders and a laptop with the plant's code subscriptions: the sections of the ASME Boiler and Pressure Vessel Code that apply to the plant, the National Board Inspection Code, and the Ohio boiler law and rules. When Tamar Ellingsen asked how the chief engineer decided what rules applied to a repair or a new piece of equipment, Grazyna pulled down the binders one at a time. "Nobody memorizes these," she said. "What you need is to know which document answers which question, and in what order they apply. The exam asks the same thing."

This lesson explains how boiler law and codes fit together in Ohio: the state law and rules, the ASME Boiler and Pressure Vessel Code and its certification marks, and the National Board, its registration and its inspection code. Lesson 11 covers inspections, repairs and records under these rules.

Laws, regulations, standards and codes

Boiler safety rests on a hierarchy of documents, each with a different kind of authority:

  • An act or statute, passed by the legislature, sets out the broad duty to keep equipment safe and creates the authority that enforces it.
  • Regulations or rules, made under the act, set out specific requirements: what must be registered, inspected and certified, who may operate it, and which codes apply.
  • Codes and standards, written by standards organizations such as CSA Group, ASME and the National Board, give the detailed technical rules. A code has legal force only when the act or regulation adopts it, often with changes or additions.
  • Code adoption documents, interpretations and code cases keep the rules current between editions and clarify how they apply.

When documents disagree, the law prevails over the code, and a jurisdiction's amendments prevail over the code text it adopts. The owner of the equipment is responsible for meeting all of them.

Hierarchy of boiler rules from the act at the top through regulations to adopted codes and standards, with the main ASME sections shown at the bottom.
How boiler laws, regulations and codes fit together.

The Ohio framework

In Ohio, boilers come under Chapter 4104 of the Ohio Revised Code, enforced by the state's boiler section in the Division of Industrial Compliance. The detailed rules are in the Ohio Administrative Code. Several pieces matter most to a stationary engineer:

  • The boiler law requires boilers to be built to the ASME code, registered, inspected before use and at set intervals, and to carry a valid certificate of operation. It also adopts the National Board Inspection Code for repairs and alterations.
  • The licensing law for stationary engineers sets who may operate a boiler above certain sizes and the classes of license (PWR-110). Ohio's high pressure boiler operator and stationary steam engineer licenses are issued by the state.
  • The state's inspection rules, which set inspection intervals, allow inspections by state inspectors or by commissioned inspectors employed by insurance companies, and require accidents to be reported.

The ASME code in Ohio

Ohio, like most states, adopts the ASME Boiler and Pressure Vessel Code by reference for new construction, so the ASME code's design, fabrication, inspection and testing rules have the force of state law. The state adds its own requirements:

  • Every boiler must be registered with the state before it is operated, with its ASME data report and its National Board registration.
  • Boilers must be inspected and given a certificate of operation before they are placed in service, and the certificate must be posted.
  • Repairs and alterations must follow the National Board Inspection Code and be done by organizations authorized under it (lesson 11).

Because Ohio adopts ASME and the NBIC by reference, a boiler built to ASME Section I and registered in Ohio meets both. The operator's job is not to know every clause but to recognize when a change, a repair or a new item of equipment brings these rules into play, and to bring in the chief engineer, the inspector or the state at that point.

State registration and the National Board number

Before a boiler can be operated in Ohio, it must be registered with the state, which records its ASME data report, its National Board registration number and its location, and assigns a state number. Most boilers are registered with the National Board by the manufacturer, which files the data report and gives the boiler an NB number stamped on its nameplate. That number lets any inspector in any state find the original data report.

A boiler at Cantwell therefore carries its ASME stamping, its NB number and its Ohio state number. If the plant buys a replacement safety valve, a new gauge glass or a vessel such as a blowdown tank, Grazyna checks that it carries the right ASME marking and, where required, National Board registration before it is installed. Equipment without them cannot legally be put in service.

The ASME Boiler and Pressure Vessel Code

The ASME Boiler and Pressure Vessel Code began after a series of deadly boiler explosions in the late 1800s and early 1900s led to calls for uniform rules (lesson 12). The first edition, covering power boilers, appeared in 1914 and 1915. It is now published every two years in many sections. The ones a power engineer meets most often are:

Main sections of the ASME Boiler and Pressure Vessel Code (in our own summary).
SectionCovers
IPower boilers: steam boilers above 15 psi (about 103 kPa) and high-temperature water boilers, with their external piping
IIMaterials: specifications (Parts A, B and C) and allowable stresses and properties (Part D)
IVHeating boilers: low-pressure steam and hot water heating boilers
VNondestructive examination methods
VIRecommended guidelines for the care and operation of heating boilers
VIIRecommended guidelines for the care of power boilers
VIIIPressure vessels, in three divisions of increasing rigor
IXWelding, brazing and fusing qualifications
XIIIRules for overpressure protection, including safety and relief valves

Section VII is especially useful to operators: it describes, in plain guidance rather than mandatory rules, how to start up, operate, shut down, lay up and inspect power boilers and their auxiliaries. Many plant procedures, including Cantwell's, are built on it.

Between editions ASME issues code cases, which allow alternatives or new materials before they are written into the code, and interpretations, which answer formal questions about what the code means. Neither changes the law in a jurisdiction until that jurisdiction accepts it.

Certification marks and designators

A manufacturer that builds to the ASME code must hold an ASME certificate of authorization, which requires a written quality control system reviewed by ASME and an agreement with an Authorized Inspection Agency. The manufacturer then applies the ASME certification mark (a cloverleaf-shaped symbol) to the nameplate, with a designator showing the section it was built to:

  • S for power boilers built to Section I; A for assembly of power boilers; M for miniature boilers; E for electric boilers; PP for power piping.
  • H for heating boilers built to Section IV.
  • U for pressure vessels built to Section VIII Division 1, and U2 and U3 for Divisions 2 and 3.
  • V for safety valves for power boilers, HV for heating boiler valves, and UV for pressure vessel relief valves.

The nameplate also shows the manufacturer, the serial number, the year built, the MAWP, the heating surface or capacity, and the National Board number where the boiler is registered. Operators should read the nameplate of every pressure item in their plant at least once. It answers most questions about what the item is and what it may be used for.

Hydrostatic tests

Every code boiler and vessel is hydrostatically tested before it leaves the shop: it is filled with water, all air is vented, and the pressure is raised to a test pressure above the MAWP and held while the inspector examines it. Water is used because it stores very little energy when compressed, so a failure during the test releases little energy. For a Section I power boiler the test pressure is typically 1.5 times the MAWP; for a Section VIII Division 1 vessel it is typically 1.3 times, with corrections for temperature.

Worked problem

Shop hydrostatic test pressure

Boiler 3's MAWP is 200 psi. What was its Section I hydrostatic test pressure? What would a Section VIII Division 1 blowdown tank with an MAWP of 150 psi typically be tested to?

Show solution
  1. \[200 \times 1.5 = 300 \text{ psi}\]
  2. \[150 \times 1.3 = 195 \text{ psi}\]

Answer: The boiler was tested at 300 psi, as its data report shows. The blowdown tank would typically see about 195 psi before any temperature correction. Tests after repairs, and tests at inspections, have their own rules set by the inspection code and the inspector, and are never simply chosen by the plant.

Note that water at the test pressure would be dangerous if it were hot. At the saturation temperature for 314.7 psia, about 422 °F, a test failure would flash the water explosively. That is why hydrostatic tests are done with water only warm enough to avoid condensation and brittle fracture, typically somewhere between about 70 and 120 °F, never with a hot boiler.

The National Board

The National Board of Boiler and Pressure Vessel Inspectors is an organization of the chief boiler inspectors of the US states, Canadian provinces and other jurisdictions. It promotes uniform enforcement of boiler rules. Its main activities are:

  • Registration: manufacturers file the data reports of registered boilers and vessels with the National Board, which keeps them on record, and the item receives an NB number.
  • Commissioning inspectors: inspectors who pass the National Board's examination and meet its experience requirements hold a commission, recognized by member jurisdictions.
  • The National Board Inspection Code (NBIC), published as NB-23, which covers what happens after a boiler is built: Part 1, installation; Part 2, inspection; and Part 3, repairs and alterations.
  • Certificates of authorization for repair organizations: the R certificate for repairs and alterations to pressure-retaining items, the VR certificate for repair of pressure relief valves, and the NR certificate for nuclear repairs. An R certificate holder must have a quality system and work under the acceptance of an inspector, and marks completed work with an R stamp on a nameplate.

In Ohio the NBIC has the force of state rules for repairs and alterations. A welded repair to a pressure part at Cantwell must be done by an R certificate holder, under the acceptance of an inspector, and documented on the National Board's repair or alteration report form (lesson 11).

Applying the rules: a worked case

Grazyna used the September study of an economizer for boiler 2 (lesson 3) as an example of how the documents fit together. If the economizer were added, it would be a pressure part of the boiler: it would need construction to ASME Section I by a manufacturer holding the right certificate, installation as an alteration under NBIC Part 3 by an R certificate holder, with the inspector's acceptance, and an updated registration and certificate of operation from the state. The boiler's records would be updated, and the operating procedures and training revised under the plant's management of change. "None of that is in the economizer's price," she said, "but all of it is in the project."

Finding the answer in the documents

Grazyna's advice for the exam and for the job was the same: start with the question, then pick the document. A few examples show how:

  • Is this replacement relief valve allowed on our deaerator? Check its nameplate for the ASME mark and designator and its National Board capacity certification, then confirm its set pressure and capacity against the vessel.
  • What thickness was the mud drum when new? The manufacturer's data report.
  • How should a power boiler be laid up for the summer? ASME Section VII's guidance, the manufacturer's manual and the treatment supplier's program, written into the plant's procedure.
  • Who may operate this boiler, and what license is needed? The state licensing law for stationary engineers and boiler operators.
  • What must happen before we weld on a boiler? NBIC Part 3, the contractor's R certificate program and the inspector's acceptance.

Codes are revised regularly, so the edition matters. A question answered from an old edition may have a different answer today, and the edition in force is the one the jurisdiction has adopted, not necessarily the newest one published. Grazyna keeps a note in each binder of the edition and the date it took effect, and checks the regulator's notices each year for changes.

Common mistakes

  • MistakeThinking a code has legal force by itself.

    InsteadIt applies only where the law adopts it, with the jurisdiction's amendments.

  • MistakeInstalling a replacement valve or vessel without checking its marking and registration.

    InsteadOhio requires ASME construction and, where required, National Board registration.

  • MistakeTreating Section VII as a set of mandatory rules.

    InsteadIt is recommended guidance on care and operation, used as the basis for procedures.

  • MistakeHydrostatic testing with hot water.

    InsteadUse water only warm enough to avoid condensation and brittle fracture.

  • MistakeAssuming any welding shop can repair a boiler.

    InsteadRepairs need an R certificate holder working under an inspector's acceptance.

Summary and key terms

  • In Ohio, ORC Chapter 4104 and the state's rules govern boilers, adopting the ASME code and the NBIC; a separate law licenses stationary engineers.
  • Boilers must be registered with the state and inspected, and must carry a valid certificate of operation.
  • Most boilers are registered with the National Board and carry an NB number linking them to their data report.
  • The ASME code's main sections include I (power boilers), II (materials), IV (heating boilers), VII (care of power boilers), VIII (pressure vessels) and IX (welding).
  • The ASME certification mark carries a designator such as S, H, U or V showing the section the item was built to.
  • The National Board registers boilers, commissions inspectors, publishes the NBIC (Parts 1 to 3) and issues R and VR certificates; Section I boilers are hydrostatically tested at typically 1.5 times MAWP.
Code adoption
The legal act by which a jurisdiction gives a code the force of law, often with amendments.
Canadian Registration Number
The number issued by a provincial regulator when a design or fitting is registered.
ASME certification mark
The symbol applied by an authorized manufacturer to show construction to an ASME code section.
Designator
The letter or letters with the ASME mark that show which code section applies, such as S or U.
National Board Inspection Code
The National Board code covering installation, inspection, and repairs and alterations (NB-23).
R certificate
A National Board authorization to repair and alter pressure-retaining items.
Code case
An ASME ruling that allows an alternative or new material before it is included in the code.
Hydrostatic test
A pressure test with water at a pressure above the MAWP to prove strength and tightness.

Practice problems

Work each problem on paper first, then reveal the answer to check.

  1. Which ASME section covers power boilers?

    Show answer

    Section I.

  2. Which designator would appear on a Section VIII Division 1 vessel?

    Show answer

    U.

  3. What is the Section I hydrostatic test pressure for a boiler with an MAWP of 150 psi?

    Show answer

    225 psi.

  4. What does an NB number on a nameplate show?

    Show answer

    That the boiler's data report is registered with the National Board.

  5. Which part of the NBIC covers repairs and alterations?

    Show answer

    Part 3.

Lesson quiz · 5 questions

Score 60% or more to complete this lesson.