IRW-340 · Lesson 3 of 12 · 21 min
Review: safety and fall protection
▶ Video coming soon A video version of this lesson is on the way.
Grace Ndlovu, Crossbeam's safety coordinator, came to the first review session with a cardboard box. In it were a harness with a frayed web, a self-retracting lifeline with a bent snap hook, a beam clamp with a cracked jaw, a lanyard whose energy absorber had partly deployed, and the damaged lifeline Shay had tagged out on his fourth day on the job. She put them on the table and asked Benno to find what was wrong with each one, out loud, in the order he would check them on a real morning. Then she said: "That's the exam. Not this box exactly, but this kind of thinking. Most safety questions ask what you'd do next, and what you'd do next is always to find the hazard and stop it before it hurts somebody."
Safety is part of the common occupational skills area, and it also runs through every other area: a rigging question may be about a damaged sling, an erection question about a column that is not yet stable, an ornamental question about an open edge at a stair. This lesson reviews the safety and fall protection material from IRW-110 and the safety parts of the later courses, in the order the group went through it.
The rules that govern the work
On an Ontario construction project, the Occupational Health and Safety Act sets the general duties and the Construction Projects regulation (O. Reg. 213/91) sets the specific rules. The constructor has overall responsibility for the project, the employer for its own workers, the supervisor for the workers he directs, and each worker for working safely and reporting hazards. Every worker has the right to know about hazards, the right to take part in health and safety, and the right to refuse unsafe work. A worker who refuses tells the supervisor, the supervisor investigates with a worker representative, and if the worker still believes the work is unsafe, a Ministry inspector is called.
Fall protection training is a legal requirement in Ontario. A worker who may use a fall protection system must complete a Working at Heights course approved by the Chief Prevention Officer, and the training is valid for three years. Crossbeam keeps the dates on its training matrix and books refreshers before they expire. The employer must also train each worker on the specific equipment and site, which is what Grace's orientation and toolbox talks do.
Fall protection: when it is required
Under the Ontario regulation, a worker who may fall 3 m or more, or who may fall into operating machinery, water, a hazardous substance or onto a hazard, must be protected. The regulation prefers guardrails, then travel restraint, then fall-restricting systems, then fall arrest, then safety nets. Crossbeam's own rule is stricter: 100 in 100 tie-off whenever a worker is above 1.8 m (6 ft) with no guardrail. That is a company rule, and a candidate should know both the legal threshold and the reason a contractor sets a lower one.
| Situation | Rule | Source |
|---|---|---|
| Possible fall of 3 m or more | Protection required, guardrail preferred | O. Reg. 213/91 |
| Fall into machinery, water or a hazardous substance | Protection required at any height | O. Reg. 213/91 |
| Any work above 1.8 m with no guardrail | 100 in 100 tie-off | Crossbeam rule |
| Openings in floors and roofs | Covered, secured and identified, or guarded | O. Reg. 213/91 (opening covers) |
| Before using a fall protection system | CPO-approved Working at Heights training, valid three years | O. Reg. 297/13 |
The fall arrest system
A personal fall arrest system has three parts that must work together: the anchor, the body harness and the connecting device between them, either an energy-absorbing lanyard or a self-retracting lifeline (SRL). The ABCs are an easy way to remember them: anchorage, body support, connector. A fourth part is just as important and often forgotten: a rescue plan.
- Anchors must be strong enough for the fall. A common rule for an anchor that has not been designed by an engineer is about 22 kN per worker attached; the manufacturer's rating for a beam clamp, sling or anchor device governs.
- The harness is a full-body harness with the back D-ring between the shoulder blades, fitted snugly so that two fingers fit under each strap, with the leg straps tight and the chest strap at mid-chest.
- Energy-absorbing lanyards are commonly 1.8 m long and limit the arresting force on the worker; the regulation limits the arrest force on the body to 8 kN. The absorber can deploy up to about 1.2 m.
- SRLs reel out and lock on a sudden pull, so free fall is short, often about 0.3 m. Class 1 SRLs are for anchors overhead; Class 2 and leading-edge models are for anchors at foot level, where the line may run over an edge.
- Every part is inspected before each use by the worker and at set intervals by a competent person. Anything that has arrested a fall is taken out of service.
Grace's box was a reminder of what that inspection finds: frayed or cut webbing, burn marks from welding spatter, a deployed energy absorber, a hook gate that does not close by itself, a cracked or bent clamp jaw, a lifeline that does not retract fully. Shay found an abraded lifeline near the snap hook at his first morning inspection in September and tagged it out. That is exactly the answer an exam question about inspection wants: remove it from service and report it, never repair it on site.
Clearance
A fall arrest system only works if the worker stops before hitting the level below. The clearance needed below the anchor or working surface adds up everything that happens in a fall. A question on clearance is almost always a calculation question, and the usual mistake is leaving out one of the pieces.
Worked problem
Lanyard or SRL at the second floor
This is the same calculation as in IRW-110. A worker is on second-floor beams 4.3 m (14 ft) above the slab, with the anchor at the height of the back D-ring. Compare a 1.8 m (6 ft) energy-absorbing lanyard (deployment up to 1.2 m (4 ft)) with an overhead SRL (free fall about 0.3 m (1 ft), arrest distance up to 1.07 m (3.5 ft)), using harness stretch of 0.3 m (1 ft) and a safety margin of 0.9 m (3 ft).
Show solution
- With the anchor at D-ring height, the feet drop the same distance as the D-ring.
- Lanyard: 1.8 + 1.2 + 0.3 + 0.9 = 4.2 m.
- SRL: 0.3 + 1.07 + 0.3 + 0.9 = 2.57 m, about 2.6 m.
- Available: 4.3 m, less anything on the slab.
Answer: The lanyard needs 4.2 m of the 4.3 m available, with no room for anything on the slab, so it is not acceptable. The SRL needs about 2.6 m (8.5 ft) and is the right choice. At low heights, lanyards often do not have enough clearance.
A second clearance trap is the anchor at foot level. If the anchor is below the D-ring, the free fall is the lanyard length plus the height of the D-ring above the anchor. A 1.8 m (6 ft) lanyard clipped to a beam clamp at the feet, 1.5 m (5 ft) below the D-ring, gives about 3.3 m (11 ft) of free fall, far more than an ordinary lanyard is built for. That is why Crossbeam's connectors use leading-edge SRLs anchored as the maker allows.
Rescue
A worker hanging in a harness after a fall is in danger even if unhurt. Suspension in a harness can restrict blood return from the legs, and a worker who is not rescued quickly can lose consciousness. The harness's trauma straps, loops the worker can stand in, buy time but do not replace rescue. Every job needs a written rescue plan before work at height starts, with the equipment on site and workers trained to use it.
Crossbeam's target is to reach and relieve a suspended worker within six minutes. At the September rescue drill on Shay's first week, the crew reached the suspended worker with the boom lift and had him on the platform in 5 minutes 10 seconds: 30 seconds to raise the alarm, 45 to get the lift moving, 200 seconds to reach him and 35 to secure him. An exam question that asks what should be in place before work at height starts expects the rescue plan in the answer, not just the harness.
Hazards of steel erection
IRW-110 listed the hazards that hurt ironworkers most often, and every later course came back to them. A candidate should be able to name each one and its main control.
| Hazard | Main controls |
|---|---|
| Falls from height | Guardrails or tie-off, inspected equipment, rescue plan |
| Collapse of an unstable structure | Erection plan, required bolts and bracing before release, guying, engineered temporary works |
| Struck by loads and falling objects | No one under the load, tag lines, controlled access zones, tool lanyards, toe boards |
| Caught between | Keep hands off landing loads, use push sticks and tag lines, stay out of pinch points at the crane |
| Crane and power line contact | Minimum distances, a dedicated signaller, a spotter near lines |
| Hot work | Hot work permit, combustibles cleared, fire watch, cylinders secured |
| Impalement on rebar | Engineered caps or troughs designed for impalement, not plastic mushroom caps |
| Noise, dust and fumes | Hearing protection, ventilation and respirators, silica controls for drilling |
| Weather | Wind limits, stop work for lightning, heat and cold plans |
Power line limits come up often. Under the Ontario regulation, no part of a crane or its load may come closer than 3 m to an energized line of 750 V to 150 kV, 4.5 m for 150 to 250 kV and 6 m for 250 to 500 kV, unless the constructor's written procedures and the conditions in the regulation are met. Noise exposure in Ontario is limited to 85 dBA averaged over eight hours, with a 3 dB exchange rate, so each 3 dB louder halves the allowed time.
Impalement protection is another frequent question. The Ontario regulation requires protruding reinforcing steel and similar ends to be removed, cut off or otherwise protected. Plastic mushroom caps keep scratches off a passing arm but will not stop a falling worker; where a worker could fall onto bars, Crossbeam uses steel-reinforced caps or wooden troughs designed for the purpose, as IRW-130 described.
Weather limits
Wind is the hazard that stops steel work most often. Crossbeam's rules, from IRW-110 and IRW-330, are company rules, set below the limits in equipment manuals: connecting stops at gusts of 50 km/h (30 mph), decking at 40 km/h (25 mph), metal building frames are not set in gusts above 40 km/h (25 mph) and panels stop at about 30 km/h (20 mph). Crane limits come from the crane's manual and the load's sail area. Lightning stops all work at height and crane work until the storm has passed by a safe margin.
Practice questions
Question 1. A worker is about to tie off to a beam clamp at his feet with an ordinary 1.8 m (6 ft) energy-absorbing lanyard. What is the main problem? Options: (a) the clamp is too strong; (b) the free fall will be the lanyard length plus the height of the D-ring above the anchor, far more than the lanyard is designed for; (c) the lanyard is too short to reach; (d) there is no problem.
Answer and reasoning: (b). With the anchor at the feet, the free fall grows by the height of the D-ring above the anchor, about 1.5 m (5 ft), giving about 3.3 m (11 ft). A leading-edge SRL rated for foot-level anchors is the right equipment.
Question 2. During a rescue drill, a worker hangs in a harness for several minutes before he is reached. Why does time matter so much? Options: (a) the harness may slip; (b) hanging motionless can restrict blood flow and lead to loss of consciousness; (c) the anchor will fail; (d) it does not matter if he is not injured.
Answer and reasoning: (b). Suspension trauma can harm an uninjured worker; rescue plans set a short target time, six minutes at Crossbeam.
Question 3. A connector refuses to go out on the steel because the wind is gusting hard and he believes the work is unsafe. What happens next under Ontario law? Options: (a) he is disciplined; (b) the supervisor investigates with a worker representative, and if he still believes it is unsafe, an inspector is called; (c) he must go out anyway; (d) the crane operator decides.
Answer and reasoning: (b). The right to refuse unsafe work and its procedure are in the Occupational Health and Safety Act; Crossbeam's wind rule would also have stopped connecting at gusts of 50 km/h.
Question 4. Which inspection finding means a harness must be removed from service? Options: (a) a little dirt on the webbing; (b) a burn mark from welding spatter on a strap; (c) the label is easy to read; (d) the buckles work smoothly.
Answer and reasoning: (b). Heat damage weakens webbing, and any doubt about a harness means it comes out of service.
Common mistakes
MistakeClipping a 1.8 m (6 ft) lanyard to an anchor at the feet.
InsteadFree fall becomes the lanyard length plus the D-ring height above the anchor; use a leading-edge SRL rated for foot-level anchors.
MistakeForgetting the safety margin or the harness stretch in a clearance calculation.
InsteadAdd free fall, deceleration, stretch and margin, then compare with the distance available.
MistakeTreating trauma straps as a rescue plan.
InsteadStraps buy minutes; a written plan, equipment and trained workers bring the worker down.
MistakeUsing plastic mushroom caps as impalement protection.
InsteadUse caps or troughs designed to stop a falling worker.
MistakeRepairing a damaged lanyard or SRL on site.
InsteadRemove it from service, tag it and report it.
Summary and key terms
- O. Reg. 213/91 requires fall protection at 3 m and over hazards at any height; Crossbeam requires tie-off above 1.8 m.
- A fall arrest system is anchor, harness and connector, inspected before every use, plus a rescue plan.
- Clearance is free fall plus deceleration plus harness stretch plus a safety margin; foot-level anchors add the D-ring height to the free fall.
- Crossbeam's rescue target is six minutes; the drill took 5 minutes 10 seconds.
- The main hazards are falls, collapse, struck by, caught between, power lines, hot work, impalement, noise and dust, and weather.
- Wind limits are company rules below the equipment limits.
- Personal fall arrest system
- An anchor, a full-body harness and a connecting device that stop a worker who falls.
- Self-retracting lifeline
- A connector that reels out and locks on a sudden pull, limiting free fall.
- Free fall
- The distance a worker falls before the system begins to slow the fall.
- Clearance
- The distance needed below the working level for a fall to be stopped safely.
- Suspension trauma
- Harm caused by hanging motionless in a harness after a fall.
- Travel restraint
- A system that keeps a worker from reaching a fall hazard at all.
Practice problems
Work each problem on paper first, then reveal the answer to check.
At what fall height does the Ontario regulation require fall protection?
Show answer
3 m, or any height over machinery, water, hazardous substances or other hazards.
Name the three parts of a fall arrest system.
Show answer
Anchor, full-body harness and connector (lanyard or SRL).
A 1.8 m lanyard is clipped 1.5 m below the D-ring. What is the free fall?
Show answer
1.8 + 1.5 = 3.3 m.
What should be done with a lanyard whose absorber has partly deployed?
Show answer
Remove it from service and report it.
What is the minimum distance from a 120 kV line for a crane in Ontario under the regulation?
Show answer
3 m.
Lesson quiz · 5 questions
Score 60% or more to complete this lesson.
Create a free account to save your progress, take quizzes and earn a certificate.