Data Centre Power Distribution

Medium- and low-voltage distribution from the utility service to the rack, designed to the Canadian Electrical Code.

DCE-310 Year 3 3 credits 12 lessons · 6 h 11 min

Offered by HSM University · Data Centre Engineering

This is the Canadian version of this course. See the American version.

What you'll learn

  • Describe how data centres connect to the grid, calculate currents at transmission and distribution voltages, size substation transformers with redundancy, and evaluate power factor and electricity bills
  • Estimate facility load from measured IT power, design-day mechanical load, diversity and redundancy, and plan phased growth and AI load dynamics
  • Select medium-voltage arrangements and switchgear, and calculate transformer full-load current, fault current, losses and efficiency
  • Specify medium-voltage cables and insulation levels, derate duct banks for mutual heating, calculate feeder drop and losses, and size neutral grounding resistors
  • Lay out low-voltage distribution from switchboards through UPS, PDUs, busway and rack PDUs, sizing circuits for continuous load and A/B redundancy at 208 V and 415 V
  • Size low-voltage feeders through overcurrent protection, corrected ampacity, parallel sets, voltage drop and harmonic neutral current
  • Estimate short-circuit currents, check equipment ratings and coordination, and reduce arc flash incident energy
  • Assess sags against the ITI curve, plan ride-through for mechanical loads, and quantify harmonics, K-factor, unbalance and leading power factor
  • Explain fault return paths and neutral bonding, calculate electrode resistance and tolerable touch voltage, and apply telecom bonding, lightning and surge protection
  • Design metering for PUE and capacity management, apply the A + B rule, choose communication protocols, plan load shedding and secure the monitoring network
  • Apply the electrical code and workplace safety standards to continuous loads, ground fault protection, grounding and bonding, working space, labelling, standby systems and commissioning
  • Produce electrical design deliverables and studies, maintain systems to NFPA 70B or CSA Z463, and evaluate emerging high-power DC and MV architectures

Course content

12 lessons · 6 h 11 min total · final exam

  1. 1 Utility service and substations 34 min · quiz
  2. 2 Load estimation and capacity planning 32 min · quiz
  3. 3 Medium-voltage switchgear and transformers 31 min · quiz
  4. 4 Medium-voltage cables, duct banks and system grounding 27 min · quiz
  5. 5 Low-voltage switchboards, busway and PDUs 32 min · quiz
  6. 6 Low-voltage conductors, raceways and circuit sizing 31 min · quiz
  7. 7 Short circuit, coordination and arc flash 33 min · quiz
  8. 8 Power quality, harmonics and ride-through 31 min · quiz
  9. 9 Grounding, bonding, lightning and surge protection 30 min · quiz
  10. 10 Metering, monitoring and control 30 min · quiz
  11. 11 Electrical code requirements 30 min · quiz
  12. 12 Design deliverables, maintenance and the future of data centre power 30 min · quiz
  13. E Final exam 20 questions

Requirements

Recommended background. You can start any course at any time.

Description

Medium- and low-voltage distribution from the utility service to the rack, designed to the Canadian Electrical Code.

Part of the Engineering stream, typically taken in year 3.