PWR-110 · Lesson 9 of 12 · 34 min

Basic plant math and units

▶ Video coming soon A video version of this lesson is on the way.

On Monday, October 26, 2026, the steam flow meter on the header read 32,200 lb/h, the deaerator gauge read 5 psi, the barometer in the control room read 29.47 inches of mercury, and a supplier's data sheet on Grazyna's desk gave a new pump's capacity in liters per second. Tamar spent her break turning everything into the same units on a scrap of log paper. Lorne looked over her shoulder and pointed at one line. "Gauge or absolute?" he asked. She had added the barometer reading to a pressure that was already absolute. It was a small mistake on paper; in a steam table it would have given her the wrong temperature by several degrees.

Stationary engineers in the US work mostly in US customary units, but they meet SI units every day on imported equipment, newer instruments and manufacturers' data, and the licensing exams expect both. This lesson covers the units of a boiler plant, how to convert between them, the difference between gauge and absolute pressure, and the handful of calculations that come up on every shift. Calculators are fine; what matters is knowing which units go in and checking that the answer makes sense.

Units and prefixes

The SI system is built from a few base units, such as the meter for length, the kilogram for mass, the second for time, the kelvin for temperature and the ampere for electric current, and units made from them, such as the newton for force, the pascal for pressure, the joule for energy and the watt for power. Prefixes scale them by powers of ten: kilo (k) means a thousand, mega (M) a million, milli (m) a thousandth and micro (µ) a millionth. A steam pressure of 1,035 kPa is 1.035 MPa; a boiler of 8,000 kW is 8 MW.

The US customary system has its own units: the foot and inch, the pound (used for both mass and force, which is a common source of confusion), the degree Fahrenheit, the British thermal unit (Btu), and pounds per square inch (psi) for pressure. Many plants mix the two, so conversion factors are part of every engineer's toolkit.

Common units in a boiler plant and their conversions.
QuantitySI unitUS customary unitConversion (rounded)
Lengthmeter (m)foot (ft), inch (in)1 m = 3.281 ft; 1 in = 25.4 mm
Masskilogram (kg)pound (lb)1 kg = 2.205 lb
Volumecubic meter (m³), liter (L)cubic foot (ft³), US gallon (gal)1 m³ = 1,000 L = 35.31 ft³; 1 gal = 3.785 L
Pressurekilopascal (kPa)pound per square inch (psi)1 psi = 6.895 kPa; 1 bar = 100 kPa
Energykilojoule (kJ)British thermal unit (Btu)1 Btu = 1.055 kJ
Powerkilowatt (kW)Btu per hour, horsepower1 kW = 3,412 Btu/h; 1 hp = 0.7457 kW
Boiler outputkilowatt (kW)boiler horsepower (BoHP)1 BoHP = 33,475 Btu/h = 9.81 kW
Water flowliters per second (L/s)US gallons per minute (gpm)1 gpm = 0.0631 L/s
A set of conversion ladders drawn as paired scales. Pressure: kPa against psi with marks at 100, 500, 1,000 and 1,380 kPa. Temperature: Celsius against Fahrenheit from 0 to 200 degrees Celsius, with water freezing, boiling and the boiler water temperature marked. Power: kW against Btu per hour and boiler horsepower.
Conversion ladders for pressure, temperature and power.

Gauge pressure and absolute pressure

The air around us presses on everything with atmospheric pressure, about 14.7 psi at sea level, a little less at higher elevations and changing slightly with the weather. Most pressure gauges in a plant read gauge pressure: the pressure above atmospheric, so they read zero when open to the air. Absolute pressure is measured from a perfect vacuum, so it equals gauge pressure plus atmospheric pressure. Steam tables and many calculations need absolute pressure; gauges and nameplates use gauge pressure. Pressures below atmospheric are called vacuum, measured as how far below atmospheric they are, often in inches of mercury (in Hg), where a perfect vacuum is about 29.92 in Hg at sea level.

Engineers write which is meant: psig for gauge pressure and psia for absolute pressure. In SI the same idea is written kPa(g) and kPa(a). When a figure has no label, the context usually means gauge pressure, but on exams and in calculations it pays to check.

A vertical scale with a perfect vacuum at the bottom, atmospheric pressure partway up, and the boiler operating pressure near the top. Brackets on the left show absolute pressure measured from vacuum; brackets on the right show gauge pressure measured from atmospheric, and vacuum below atmospheric.
Gauge pressure is measured from the atmosphere; absolute pressure from a perfect vacuum.

Worked problem

Gauge to absolute

The boiler steam gauge reads 150 psig and the barometer reads 29.47 in Hg, which is 14.47 psi. What is the absolute pressure? And what is 150 psig in kPa?

Show solution
  1. Absolute:
  2. \[150 + 14.47 = 164.47 \text{ psia}\]
  3. In kPa:
  4. \[150 \times 6.895 \approx 1{,}034 \text{ kPa(g)}\]

Answer: About 164.5 psia, and the gauge reading is about 1,034 kPa gauge. Tamar's mistake was to add the barometer reading a second time to a figure that was already absolute.

Pressure also comes from a column of liquid. A column of water 1 ft high exerts about 0.433 psi at its base, which is why a gauge at the bottom of a tall tank reads more than one at the top, and why a pump's suction pressure depends on how high the water level in the deaerator stands above it. Low pressures, such as draft in a furnace or a fan's pressure, are often given in inches of water column (in. w.c.), where 1 psi is about 27.7 in. w.c..

Temperature

Temperature scales differ in their zero points and the size of their degrees. On the Celsius scale water freezes at 0 °C and boils at 100 °C at atmospheric pressure; on the Fahrenheit scale the same points are 32 °F and 212 °F. A change of 1 °C equals a change of 1.8 °F. Absolute scales start at absolute zero: the kelvin (K) uses Celsius-sized degrees, so K = °C + 273.15, and the Rankine (°R) uses Fahrenheit-sized degrees, so °R = °F + 459.67. Gas law calculations need absolute temperatures.

Worked problem

Converting temperatures

Feedwater leaves the deaerator at about 221 °F. Convert it to Celsius and to Rankine.

Show solution
  1. To Celsius:
  2. \[(221 - 32) \div 1.8 = 105 \ ^\circ\text{C}\]
  3. To Rankine:
  4. \[221 + 459.67 = 680.67 \ ^\circ\text{R}\]

Answer: 221 °F is 105 °C and about 681 °R. A temperature difference converts differently: a rise of 18 °F is a rise of 10 °C, with no 32 subtracted.

Heat, energy and power

Heat is energy moving because of a temperature difference. In SI it is measured in joules (J), usually kilojoules (kJ); in US units in British thermal units (Btu). One Btu is roughly the heat needed to warm one pound of water by 1 °F, and one kilojoule warms about 0.24 kg of water by 1 °C. The heat needed to change the temperature of a substance is its mass times its specific heat times the temperature change:

\[Q = m \times c \times \Delta T\]

Water's specific heat is about 1 Btu/lb·°F. Power is the rate of energy flow: a watt is a joule per second, and a kilowatt is a kilojoule per second; in US units power is often given in Btu per hour. A boiler's rating in kW or Btu per hour is therefore how fast it can deliver heat.

Worked problem

Heating water in a tank

The hot water loop's expansion tank and piping hold about 39,700 lb of water. How much heat does it take to warm it from 59 °F to 176 °F, and how long would one 10,240,000 Btu/h hot water boiler take, ignoring losses?

Show solution
  1. Heat:
  2. \[39{,}700 \times 1 \times (176 - 59) \approx 4{,}645{,}000 \text{ Btu}\]
  3. Time:
  4. \[4{,}645{,}000 \div 10{,}240{,}000 \approx 0.45 \text{ h} \approx 27 \text{ min}\]

Answer: About 27 minutes of full firing, in theory. In practice it takes longer, because heat is lost from the piping and the boiler is fired gently while the system warms, to limit thermal stress. The example shows the size of the energy involved in a modest volume of water.

Worked problem

Boiler output in different units

A boiler is rated about 27,300,000 Btu/h. Express its output in kilowatts and in boiler horsepower.

Show solution
  1. Kilowatts:
  2. \[27{,}300{,}000 \div 3{,}412 \approx 8{,}000 \text{ kW}\]
  3. Boiler horsepower:
  4. \[27{,}300{,}000 \div 33{,}475 \approx 816 \text{ BoHP}\]

Answer: About 27.3 million Btu per hour, about 8,000 kW, or about 815 boiler horsepower. Small differences in the last figure come from rounding the conversion factors.

Mass, flow and volume

Steam flow is measured as a mass flow, pounds per hour (lb/h), because the mass of steam is what carries the energy. Water flow is often given as a volume flow, US gallons per minute (gpm). For cold water, one liter has a mass of about one kilogram and one US gallon weighs about 8.34 lb; hot water is less dense, which matters for accurate tank and flow calculations.

Worked problem

Volume of a tank

The condensate receiver is a horizontal cylinder about 6 ft in diameter and 14 ft long. What is its volume in cubic feet and gallons, and roughly what weight of water does it hold when full?

Show solution
  1. Volume:
  2. \[V = \pi r^{2} L = 3.1416 \times 3^{2} \times 14 \approx 396 \text{ ft}^3\]
  3. In gallons:
  4. \[396 \times 7.48 \approx 2{,}960 \text{ gal}\]
  5. Weight at 8.34 lb/gal:
  6. \[2{,}960 \times 8.34 \approx 24{,}700 \text{ lb}\]

Answer: About 396 cubic feet or 2,960 gallons, holding roughly 24,700 lb of cold water, a little less of hot condensate.

Worked problem

Converting a pump flow

A new pump is rated at 28.4 L/s. What is that in US gallons per minute?

Show solution
  1. Conversion:
  2. \[28.4 \div 0.0631 \approx 450 \text{ gpm}\]

Answer: 450 gpm is about 28.4 L/s. A quick check: a liter per second is about 16 gpm, so 450 gpm should be a little under 30 L/s, which it is.

Checking answers

The best protection against errors is a habit of checking. Write the units on every number and carry them through the calculation; if the units of the answer are wrong, so is the answer. Estimate before calculating: a boiler of a few thousand kilowatts should take minutes to tens of minutes to heat a few metric tons of water, not seconds or days. And keep gauge and absolute pressure clearly labeled. Lorne's last word on the subject was practical: "If it doesn't look right, it probably isn't. Do it again before you act on it."

Ratios, efficiency and fractions

Much plant math is about comparing one quantity with another. Efficiency is useful output divided by input: a boiler that puts 82 units of heat into steam for every 100 units of heat in the fuel has an efficiency of 0.82, often stated as 82 in 100. Efficiency is always less than one, and a calculation that gives more than one has an error somewhere. The same kind of ratio appears in condensate return (lesson 10), cycles of concentration in water treatment (lesson 8), and load as a fraction of a boiler's rating.

Worked problem

Boiler efficiency

A boiler burns natural gas with an energy input of 33,300,000 Btu/h (heat in the fuel) and delivers 27,300,000 Btu/h to the steam. What is its efficiency, and how much heat is lost?

Show solution
  1. Efficiency:
  2. \[27{,}300{,}000 \div 33{,}300{,}000 \approx 0.82\]
  3. Heat lost:
  4. \[33{,}300{,}000 - 27{,}300{,}000 = 6{,}000{,}000 \text{ Btu/h}\]

Answer: About 0.82, with about 6,000,000 Btu/h lost, most of it as heat in the flue gas going up the stack. Plant improvements such as cleaning heating surfaces, trimming excess air and recovering condensate all aim to shrink that loss.

Reading the meters

Plant meters often show two kinds of number: a rate, such as steam flow in lb/h right now, and a totalizer, the running total since the meter was installed or reset. To find how much was used in a period, the engineer subtracts the earlier totalizer reading from the later one; to find the average rate, they divide that difference by the time. The log sheet records totalizers at fixed times for this reason.

Worked problem

Steam made in a shift

At 7:00 a.m. the steam totalizer read 106,295,000 lb and at 7:00 p.m. it read 106,681,000 lb. How much steam was made during the shift, and what was the average flow?

Show solution
  1. Steam made:
  2. \[106{,}681{,}000 - 106{,}295{,}000 = 386{,}000 \text{ lb}\]
  3. Average flow over 12 h:
  4. \[386{,}000 \div 12 \approx 32{,}200 \text{ lb/h}\]

Answer: 386,000 lb of steam, an average of about 32,200 lb/h, which matches the rate Tamar read at the start of the lesson.

Common mistakes

  • MistakeAdding atmospheric pressure to a pressure that is already absolute.

    InsteadLabel every pressure as gauge or absolute and convert only once.

  • MistakeConverting a temperature difference with the 32-degree offset.

    InsteadDifferences convert by the factor only: 10 °C of change is 18 °F of change.

  • MistakeTreating the pound as the same thing in mass and force calculations without thinking.

    InsteadKnow whether the problem is about mass (how much stuff) or force (how hard it pushes).

  • MistakeUsing cold-water density for hot water.

    InsteadHot water is less dense; use the right value for accurate mass and flow.

  • MistakeDropping units during a calculation.

    InsteadWrite units on every number and check the units of the answer.

Summary and key terms

  • SI units use prefixes such as kilo and mega; US customary units include psi, Btu and the pound.
  • Key conversions: 1 psi = 6.895 kPa, 1 Btu = 1.055 kJ, 1 kW = 3,412 Btu/h, 1 BoHP = 9.81 kW.
  • Absolute pressure equals gauge pressure plus atmospheric pressure; label which you mean.
  • A water column of 1 ft exerts about 0.433 psi.
  • °F = °C × 1.8 + 32; K = °C + 273.15; temperature differences convert by the factor only.
  • Heat equals mass times specific heat times temperature change; water's specific heat is about 1 Btu/lb·°F.
  • Estimate first, carry units and check every answer before acting on it.
Gauge pressure
Pressure measured above atmospheric pressure.
Absolute pressure
Pressure measured from a perfect vacuum; gauge plus atmospheric.
Vacuum
Pressure below atmospheric.
Specific heat
The heat needed to raise a unit mass of a substance by one degree.
Kilowatt
A unit of power equal to one kilojoule per second.
British thermal unit
The heat to raise about one pound of water by 1 °F; about 1.055 kJ.
Boiler horsepower
A unit of boiler output, about 9.81 kW or 33,475 Btu/h.

Practice problems

Work each problem on paper first, then reveal the answer to check.

  1. A gauge reads 75 psig and the barometer 14.7 psi. What is the absolute pressure?

    Show answer

    89.7 psia.

  2. Convert 80 °C to Fahrenheit.

    Show answer

    176 °F.

  3. How many Btu per hour is 1 kW?

    Show answer

    About 3,412 Btu/h.

  4. What pressure does a water column 1 ft high exert?

    Show answer

    About 0.433 psi.

  5. What is 450 US gpm in L/s?

    Show answer

    About 28.4 L/s.

Lesson quiz · 5 questions

Score 60% or more to complete this lesson.

Take the quiz