On Sunday, October 25, the practice exam session (lesson 11) had a second student. Kiran Beaulac, one week into his apprenticeship, sat at the far end of the bench with the Core and Type I practice sections of Dee's test. His EPA Section 608 Type I test was planned for early December. "You'll be recovering refrigerant from refrigerators before you've done anything else on your own," Dee told him, "so this is the first certificate you'll need. Eamon has held his Universal certification since 2024, so this is review for him and new for you."
This lesson reviews the EPA Section 608 material that APP-110, APP-210 and APP-330 applied: the Core section, which every Section 608 candidate writes, and Type I, which covers small appliances. NASTeC's refrigeration specialty assumes this knowledge, and every technician who opens a sealed system needs the certification by law.
What Section 608 certification is
Section 608 of the Clean Air Act and the EPA's regulations under it (40 CFR Part 82, Subpart F) require technicians who open appliances containing refrigerant, or who recover refrigerant, to be certified. There are four certifications: Type I for small appliances, Type II for high-pressure systems, Type III for low-pressure systems, and Universal for all three. Every type requires passing the Core section as well. Certification does not expire, but the card should be kept, because suppliers ask to see it before selling regulated refrigerant.
The EPA defines a small appliance as one that is fully manufactured, charged and hermetically sealed in a factory with 5 lb (about 2.27 kg) of refrigerant or less. That includes household refrigerators and freezers, room and window air conditioners, dehumidifiers, water coolers, vending machines and under-counter ice machines. Type I certification lets a technician recover refrigerant from and service these appliances. Most household refrigerators now use R-600a, which the EPA exempts from the venting prohibition when used in household refrigerators and freezers, but R-134a and other HFC systems are still common in the field, and the rules apply in full to them.
Ozone, climate and the history of the rules
Both the course and the exam begin with why the rules exist. Chlorofluorocarbons (CFCs) such as R-12, used in household refrigerators until the early 1990s, release chlorine when they reach the stratosphere, and chlorine destroys ozone, which shields the Earth from ultraviolet radiation. Hydrochlorofluorocarbons (HCFCs) such as R-22 do less damage but still some. The Montreal Protocol of 1987, signed by Canada and the United States, phased out CFCs and then HCFCs. Hydrofluorocarbons (HFCs) such as R-134a contain no chlorine and do not deplete ozone, but they are strong greenhouse gases, and the Kigali Amendment of 2016 added a phase-down of HFCs.
The measure of a refrigerant's climate effect is its global warming potential (GWP), the warming it causes compared with the same mass of carbon dioxide over 100 years. APP-110 used the figures for the refrigerants in Penfold's November haul-away units: CFC-12 about 10,900 and R-134a about 1,430. Hydrocarbons such as R-600a have a GWP of only about 3. That is why the newest refrigerators use R-600a, and why APP-210 and APP-330 described limits of 150 GWP for new household refrigerators and 700 for new room air conditioners and dehumidifiers in the United States, with a similar 150 limit for residential refrigeration in Canada.
Worked problem
Comparing the climate effect of two old charges
Penfold's 1992 chest freezer held 250 g of CFC-12 and its 2009 refrigerator held 150 g of R-134a. Using GWP values of 10,900 and 1,430, how many kilograms of carbon dioxide would each charge be equivalent to if released?
Show solution
- CFC-12:
- \[0.250 \times 10{,}900 = 2{,}725 \text{ kg CO}_2\text{e}\]
- R-134a:
- \[0.150 \times 1{,}430 = 214.5 \text{ kg CO}_2\text{e}\]
Answer: About 2.7 metric tons for the old freezer and about 215 kg for the 2009 refrigerator. CFC-12 also destroys ozone, which R-134a does not. Recovering both charges is required and keeps that harm out of the air.
The venting prohibition and recovery requirements
The EPA prohibits knowingly venting ozone-depleting refrigerants and their substitutes, such as HFCs, during maintenance, service, repair or disposal. Minor releases that happen during good-faith efforts to recover, such as from connecting and disconnecting hoses, are not violations. The Core exam uses three terms: recover means to remove the refrigerant and store it in an external container; recycle means to clean it for reuse, for example with oil separation and filter-driers; and reclaim means to reprocess it to the purity of new refrigerant (AHRI Standard 700), which only a certified reclaimer may do.
For small appliances the EPA sets a recovery requirement that depends on the equipment used and on whether the appliance's compressor works. With recovery equipment made after November 15, 1993, the technician must recover 90 in 100 of the charge if the appliance's compressor is working, or 80 in 100 if it is not, or evacuate the appliance to 4 inches of mercury vacuum. Recovery can be self-contained, with a recovery machine that has its own compressor, or system-dependent (passive), using the appliance's own compressor or a heated, evacuated container. Recovery equipment must be certified by an EPA-approved testing organization.
Worked problem
Checking a recovery against the requirement
Kiran's first lead call in APP-110 involved a refrigerator with a 142 g R-134a charge, and on the November 9 haul-away day Penfold recovered 141 g from a 2009 refrigerator rated 150 g. Did each recovery meet the 90 in 100 requirement for an appliance with a working compressor?
Show solution
- For the 142 g charge, 131 g recovered:
- \[131 \div 142 \approx 0.92\]
- For the 150 g charge, 141 g recovered:
- \[141 \div 150 = 0.94\]
- The minimums are 0.9 × 142 ≈ 128 g and 0.9 × 150 = 135 g; both recoveries meet them.
Answer: Yes, both meet the requirement. Penfold records each recovery's weight against the nameplate charge on the work order.
Worked problem
Filling a recovery cylinder
A recovery cylinder is rated to hold 30 lb (13.6 kg) of refrigerant when full. What is the most it should hold under the usual 80 in 100 fill limit?
Show solution
- In pounds:
- \[0.80 \times 30 = 24 \text{ lb}\]
- In kilograms:
- \[0.80 \times 13.6 \approx 10.9 \text{ kg}\]
Answer: About 24 lb (10.9 kg). The cylinder is weighed during recovery, and a scale or the machine's float switch stops filling before that point. A household refrigerator charge is a few ounces, so a cylinder lasts many recoveries; it is the running total that has to be watched.
Leak repair, disposal and records
Small appliances are not subject to the EPA's leak repair requirements, which apply to larger systems, but a leak is still found and repaired before a system is recharged, and good practice is never to add refrigerant to a leaking system. Leak tests use an electronic detector, soap solution or a standing pressure test with dry nitrogen through a regulator; oxygen and compressed air are never used. For disposal, the final processor in the chain (for Penfold, its recycler Quarrington Metal Recovery) must recover the refrigerant or verify that it was recovered earlier, and keeps a signed statement for three years, as APP-110 explained. Piercing access valves should not be left on an appliance after service, because they can leak.
Taking the Core and Type I sections
Each section has 25 questions. Taken proctored and closed-book, each section is passed with 70 in 100, which is 18 correct. Type I can also be taken open-book, online or by mail without a proctor, but the passing score is then 84 in 100, which is 21 correct, and an open-book Type I does not count toward Universal certification. Kiran chose to take Core and Type I proctored and closed-book, so that he can add Types II and III later without retaking them.
Worked problem
Kiran's practice scores
On October 25, Kiran answered 19 of 25 Core practice questions and 22 of 25 Type I practice questions correctly. Would each score pass proctored (70 in 100)? Would the Type I score pass open-book (84 in 100)?
Show solution
- Core:
- \[19 \div 25 = 0.76 \ge 0.70\]
- Type I:
- \[22 \div 25 = 0.88\]
- Open-book needs 21 of 25; 22 clears it, proctored needs 18.
Answer: Both would pass proctored, and Type I would also pass open-book. Core was the weaker section, so Dee gave Kiran the cylinder, safety and regulation chapters to reread before December.
Practice questions in the exam's style
Dee wrote fifty practice questions for Kiran, twenty-five each for Core and Type I. Six of them are here, with their answers, because the reasoning behind each is the part worth remembering.
Practice problems
Work each problem on paper first, then reveal the answer to check.
Core practice: Which refrigerants are subject to the venting prohibition during service?
Show answer
CFCs, HCFCs and their substitutes such as HFCs; isobutane in household refrigerators is exempted.
Practice: Why does a recovery machine need its own oil and filter-drier maintenance?
Show answer
It handles used refrigerant with moisture, acid and debris; a neglected machine contaminates the refrigerant and fails.
Core practice: Which agreement phases down HFCs?
Show answer
The Kigali Amendment to the Montreal Protocol (2016).
Type I practice: A refrigerator's compressor does not run. With modern recovery equipment, what must be recovered?
Show answer
80 in 100 of the charge, or the system evacuated to 4 in Hg vacuum.
Practice: Which kind of recovery uses the appliance's own compressor?
Show answer
System-dependent (passive) recovery.
Practice: Why should a piercing valve not be left on a refrigerator after service?
Show answer
It can leak over time; the process tube should be sealed by pinching or brazing as the procedure requires.
Safety in recovery
Both the course and the exam include safety around refrigerants and cylinders. Refrigerant cylinders are kept upright and secured, away from heat; they are never heated with a flame, and a cylinder that has been overfilled is dangerous because a small temperature rise can rupture it. Liquid refrigerant on skin or in the eyes causes frostbite, so gloves and safety glasses are worn. Refrigerant vapor is heavier than air and displaces oxygen in a basement or crawl space, which is why recovery is done with good ventilation. Heating refrigerant such as R-134a in a flame can produce toxic decomposition products. And recovery from a hydrocarbon system follows the maker's flammable-refrigerant procedure, with no ignition sources.
Worked problem
Recovery from a small charge
APP-210's chest freezer held 85 g of R-134a and its compressor still ran. How much refrigerant is 90 in 100 of that charge, and 80 in 100?
Show solution
- 90 in 100:
- \[0.90 \times 85 = 76.5 \text{ g}\]
- 80 in 100:
- \[0.80 \times 85 = 68 \text{ g}\]
Answer: About 76.5 g with the compressor working, or 68 g if it did not run. Penfold records the recovered weight against the nameplate charge on the work order.
Dee's last advice to Kiran was about the reasons behind the rules. "You'll forget a number," she said, "but if you remember why the rule exists, you can usually work the number out. Eighty in a hundred is about expansion. No oxygen is about explosions. Empty notices are about the next person who handles that appliance. Think about who the rule protects."
For Eamon, the review was also a reminder that certifications need records. Section 608 certification does not expire, but suppliers ask to see the card before selling regulated refrigerant, and a lost card has to be replaced through the certifying organization. Penfold's office keeps a copy of every technician's card on file, and Fenna checks the file each January.
Common mistakes
MistakeThinking R-600a in a household refrigerator is subject to every venting rule.
InsteadThe EPA exempts isobutane in household refrigerators from the venting prohibition, but safety procedures still apply.
MistakeFilling a recovery cylinder to its rated capacity.
InsteadStop at 80 in 100 of capacity, by weight.
MistakePressurizing a system with oxygen or compressed air for a leak test.
InsteadUse dry nitrogen through a regulator.
MistakeAdding refrigerant to a leaking system to keep it going.
InsteadFind and repair the leak first.
MistakeTaking Type I open-book when Universal is the goal.
InsteadTake Core and Type I proctored so they count toward Universal.
Summary and key terms
- Section 608 requires certification to open appliances containing refrigerant; Type I covers small appliances of 5 lb or less.
- Core plus each Type section has 25 questions; proctored passing is 70 in 100 (18), open-book Type I is 84 in 100 (21).
- CFCs and HCFCs deplete ozone; HFCs do not but have high GWP; hydrocarbons such as R-600a have a GWP of about 3.
- The Montreal Protocol phased out CFCs and HCFCs; the Kigali Amendment phases down HFCs.
- Recover, recycle and reclaim have different meanings; reclaim means new-refrigerant purity.
- With modern recovery equipment, recover 90 in 100 (working compressor) or 80 in 100 (not working), or pull 4 in Hg vacuum.
- Leak tests use nitrogen, never oxygen or compressed air; leaks are repaired before recharging.
- The final processor verifies recovery and keeps a signed statement for three years.
- ODP card
- Ontario's ozone depletion prevention certificate for handling halocarbon refrigerants.
- Small appliance
- A factory-sealed appliance with 5 lb or less of refrigerant (US EPA definition).
- Recover
- To remove refrigerant from a system and store it in an external container.
- Reclaim
- To reprocess used refrigerant to the purity of new refrigerant.
- GWP
- Global warming potential: warming effect compared with the same mass of carbon dioxide over 100 years.
- Piercing valve
- A clamp-on valve that pierces a process tube to give access to a system without service valves.
Practice problems
Work each problem on paper first, then reveal the answer to check.
Practice: What is the EPA's size limit for a small appliance?
Show answer
5 lb of refrigerant or less, factory charged and hermetically sealed.
Practice: What is the difference between recycling and reclaiming refrigerant?
Show answer
Recycling cleans it for reuse; reclaiming reprocesses it to the purity of new refrigerant at a certified facility.
Practice: Why is a recovery cylinder never filled past 80 in 100 of its capacity?
Show answer
So that the liquid has room to expand if the cylinder warms, preventing a dangerous pressure rise.
Practice: An appliance's compressor does not run. What share of the charge must be recovered with modern equipment?
Show answer
80 in 100, or the appliance evacuated to 4 in Hg vacuum.
Practice: Which gas is used to pressurize a system for a leak test?
Show answer
Dry nitrogen, through a regulator.
Practice: CFC-12 has a GWP of about 10,900 and R-134a about 1,430. How many times stronger is CFC-12?
Show answer
10,900 ÷ 1,430 ≈ 7.6 times.
Lesson quiz · 5 questions
Score 60% or more to complete this lesson.