INS-120 · Lesson 2 of 12 · 30 min

Heat, temperature and units

▶ Video coming soon A video version of this lesson is on the way.

At the second Friday session, Tomasz wrote two words on the whiteboard, HEAT and TEMPERATURE, and asked the apprentices what the difference was. Tessa said heat was how hot something is. Devon said temperature was how hot something is and heat was "the stuff that moves." Tomasz pointed at Devon. "Closer. Today we sort that out properly, because every number on an insulation data sheet uses one or the other, and mixing them up is how people order the wrong product."

This lesson covers the basic ideas and units of heat. Insulators do not need a physics degree, but they do need to read data sheets, specifications, thickness tables and the occasional engineering calculation, and to understand what the numbers mean. Insulators on both sides of the border also see both metric and US customary units on the same job, so converting between them is a daily skill.

Temperature and heat are different things

Temperature is a measure of how hot or cold something is. It tells you how fast the tiny particles in a material are moving on average: the faster they move, the higher the temperature. A thermometer measures temperature. Temperature does not depend on how much material there is. A cup of boiling water and a kettle of boiling water have the same temperature.

Heat is energy in transit. It is energy that moves from one place to another because of a temperature difference, always from the hotter place to the colder place. The kettle holds far more energy than the cup, even at the same temperature, because there is more water. Heat flows out of both into the cooler room, and the kettle can keep giving off heat for much longer.

This leads to the most important rule in insulation work: heat always flows from hot to cold, and the bigger the temperature difference, the faster it flows. A steam line at 186 °C (366 °F) in a room at 20 °C (68 °F) loses heat to the room. An ammonia suction line at −34 °C (−30 °F) in the same room gains heat from it. Insulators sometimes speak of "keeping the cold in," but there is no such thing as cold flowing out. On a cold line, the insulation keeps heat from flowing in.

Two insulated pipes side by side. On the left, a hot steam pipe with arrows showing heat flowing outward from the pipe through the insulation to the room. On the right, a cold refrigeration pipe with arrows showing heat flowing inward from the room through the insulation to the pipe.
Heat always flows from hot to cold: out of a hot pipe and into a cold one.

Temperature scales

Four temperature scales appear in insulation work.

  • Celsius (°C): water freezes at 0 °C and boils at 100 °C at sea level. Used in Canada and in most of the world, and in most engineering work.
  • Fahrenheit (°F): water freezes at 32 °F and boils at 212 °F. Used for most work in the United States and on many US-made data sheets sold in Canada.
  • Kelvin (K): an absolute scale that starts at absolute zero, the coldest possible temperature, where particle motion is at its minimum. A kelvin is the same size as a degree Celsius, and 0 °C is 273.15 K. Kelvin is used in some formulas, especially for radiation.
  • Rankine (°R): the absolute scale with Fahrenheit-sized degrees. Absolute zero is 0 °R, and 0 °F is about 459.67 °R. It appears in some older US engineering references.

To convert a temperature reading between Celsius and Fahrenheit, use these formulas:

\[T_{F} = T_{C} \times 1.8 + 32 \qquad T_{C} = (T_{F} - 32) \div 1.8\]
Two thermometer scales side by side, one in degrees Celsius and one in degrees Fahrenheit, with matching marks for absolute zero, liquid nitrogen, ammonia refrigeration, water freezing, the safe-to-touch limit, water boiling, medium-pressure steam and the upper limit of mineral wool pipe insulation.
Key temperatures in insulation work on both scales.

Worked problem

Converting temperatures from a job

The Kellerton steam header runs at 186 °C, the ammonia suction line at −34 °C and the safe-to-touch target is 60 °C. Convert each to Fahrenheit for a US-made data sheet.

Show solution
  1. Steam: 186 × 1.8 + 32 = 334.8 + 32 = 366.8 °F, usually rounded to 366 °F or 367 °F.
  2. Ammonia: −34 × 1.8 + 32 = −61.2 + 32 = −29.2 °F, about −30 °F.
  3. Safe to touch: 60 × 1.8 + 32 = 108 + 32 = 140 °F.

Answer: About 367 °F, −29 °F and 140 °F.

Temperature differences are converted differently

A temperature difference is not a temperature reading, and it converts without the 32. A difference of 1 °C is the same as a difference of 1.8 °F, and a difference of 1 K is the same as 1 °C. Many data sheet values, such as thermal conductivity, are given "per degree" of temperature difference, and heat-loss formulas use the difference between the inside and outside surfaces.

Worked problem

Converting a temperature difference

A steam pipe at 186 °C sits in a room at 40 °C. What is the temperature difference in Celsius degrees and in Fahrenheit degrees?

Show solution
  1. Difference in Celsius: 186 − 40 = 146 °C (often written 146 K).
  2. Difference in Fahrenheit: 146 × 1.8 = 262.8 °F. Do not add 32.
  3. Check: 186 °C is 366.8 °F and 40 °C is 104 °F, and 366.8 − 104 = 262.8 °F.

Answer: 146 °C, or about 263 °F, of difference.

The most common mistake apprentices make with units is adding or subtracting 32 when converting a temperature difference. Tomasz's rule: "If the number is a reading on a thermometer, use the 32. If it's a difference between two readings, don't."

Mean temperature

Insulation data sheets list thermal conductivity at a mean temperature, not at the pipe temperature. The mean temperature is the average of the temperatures on the two faces of the insulation: the hot (or cold) face against the pipe and the outer face against the jacket. Lesson 4 explains why this matters. For now, here is how to calculate it.

\[T_{mean} = \frac{T_{inner} + T_{outer}}{2}\]

Worked problem

Mean temperature of steam pipe insulation

The insulation on the Kellerton header has 186 °C on its inner face and about 15 °C on its outer face under the jacket. What is the mean temperature?

Show solution
  1. Mean = (186 + 15) ÷ 2 = 201 ÷ 2 = 100.5 °C.

Answer: About 100 °C. The k-value to use comes from the data sheet line for a mean of about 100 °C, not 186 °C.

Units of heat energy

Heat is energy, so it is measured in energy units. The units you will meet most often are:

Units of heat energy.
UnitWhere it is usedSize
Joule (J), kilojoule (kJ), megajoule (MJ), gigajoule (GJ)SI unit of energy; Canadian gas bills are in gigajoules1 kJ = 1,000 J; 1 GJ = 1,000,000 kJ
Kilowatt-hour (kWh)Electricity bills; energy savings reports1 kWh = 3,600 kJ = 3.6 MJ
British thermal unit (Btu)US data sheets, US energy calculations1 Btu ≈ 1.055 kJ; it is roughly the heat to warm 1 lb of water by 1 °F
ThermUS natural gas bills1 therm = 100,000 Btu ≈ 29.3 kWh
MMBtuLarge US energy quantities1 MMBtu = 1,000,000 Btu = 10 therms ≈ 1.055 GJ

The kilocalorie still appears on some older European documents. One kilocalorie is about 4.19 kJ, the heat needed to warm a kilogram of water by one degree Celsius.

Units of heat flow

Insulators deal less with total energy than with the rate at which heat flows: how much heat passes through the insulation each second or each hour. A rate of heat flow is a power.

Units of heat flow (power).
UnitWhere it is usedConversion
Watt (W), kilowatt (kW)SI unit of heat flow; heat loss per metre of pipe is given in W/m1 W = 1 J/s; 1 kW = 1,000 W
Btu per hour (Btu/h)US unit of heat flow; heat loss per foot of pipe is given in Btu/h·ft1 W ≈ 3.412 Btu/h; 1 kW ≈ 3,412 Btu/h
Ton of refrigerationSize of chillers and refrigeration plants in both countries1 ton = 12,000 Btu/h ≈ 3.517 kW
Boiler horsepowerSize of some steam boilers1 boiler hp ≈ 33,475 Btu/h ≈ 9.81 kW

Look at how the units fit together. Energy equals power multiplied by time. A pipe losing 1 kW for 10 hours loses 10 kWh. A pipe losing 1,000 Btu/h for 10 hours loses 10,000 Btu. Lesson 1 used exactly this step to turn a heat loss into a yearly energy cost.

Worked problem

Heat gain on a refrigeration line

A 40 m run of insulated ammonia suction line at Kellerton gains about 25 W of heat per metre. How much refrigeration capacity does this heat gain use, in kilowatts and in tons?

Show solution
  1. Heat gain = 25 W/m × 40 m = 1,000 W = 1.0 kW.
  2. In tons: 1.0 kW ÷ 3.517 kW per ton ≈ 0.28 tons.

Answer: About 1 kW, or 0.28 tons. That is good insulation. The iced, wet section before the repair was gaining several times as much.

Sensible heat and latent heat

When heat flows into or out of a material, one of two things happens. Either the temperature changes, or the material changes state, for example from water to steam or from water to ice, without changing temperature.

  • Sensible heat changes the temperature. You can sense it with a thermometer. The amount depends on the mass, the temperature change and the specific heat of the material, which is the heat needed to raise one unit of mass by one degree.
  • Latent heat changes the state at a fixed temperature. It is large. Melting ice takes about 334 kJ per kilogram (144 Btu per pound), and turning water into steam at atmospheric pressure takes about 2,257 kJ per kilogram (970 Btu per pound).

The sensible heat formula is simple:

\[Q = m \times c \times \Delta T\]

Here Q is the heat, m is the mass, c is the specific heat and ΔT ("delta T") is the temperature change. Water has a specific heat of about 4.19 kJ per kilogram per degree Celsius (1 Btu per pound per degree Fahrenheit), which is high: water stores a lot of heat for its weight. That is why hot water systems carry heat so well and why a tank of hot water stays hot for a long time if it is insulated.

Worked problem

Heating a tank of domestic hot water

A 1,000 L domestic hot water tank at Mountview is heated from 10 °C to 60 °C. A litre of water has a mass of about 1 kg. How much heat is needed?

Show solution
  1. Mass: 1,000 L ≈ 1,000 kg.
  2. Temperature rise: 60 − 10 = 50 °C.
  3. Q = 1,000 kg × 4.186 kJ/(kg·°C) × 50 °C = 209,300 kJ.
  4. In kilowatt-hours: 209,300 ÷ 3,600 ≈ 58.1 kWh.

Answer: About 209,000 kJ, or 58 kWh. Insulation on the tank and its piping keeps that heat from leaking away between uses.

Latent heat explains two things insulators see on the job. First, steam carries enormous energy in its latent heat, and when a steam line loses heat, the steam condenses and gives up that latent heat. Second, ice on a cold line represents a lot of heat that leaked in and froze water vapour out of the air. When the Kellerton crew removed about 238 kg (520 lb) of ice from the ammonia suction line, Marcel Ouellet pointed out that the ice had taken a great deal of refrigeration to make.

Worked problem

The heat locked in ice

Freezing water releases about 334 kJ per kilogram, which the refrigeration system must remove. How much heat was removed to freeze 238 kg of ice, ignoring the cooling of the water first?

Show solution
  1. Q = 238 kg × 334 kJ/kg = 79,492 kJ.
  2. In kilowatt-hours: 79,492 ÷ 3,600 ≈ 22.1 kWh.

Answer: About 79,500 kJ, or 22 kWh, of refrigeration, plus the heat to cool the moisture first, all wasted because of one wet section.

Metric and US customary on the same job

Canadian specifications are written in SI units, but insulators in Canada still meet US customary units every day. Pipe sizes are given as nominal pipe size (NPS), which comes from inch dimensions; many insulation products are made in inch thicknesses and labelled with both; and many data sheets come from US manufacturers and list conductivity in Btu·in/(h·ft²·°F) with the SI value second or not at all. Ontario's building and energy codes use SI, but tables from US standards often appear in specifications as well. A careful insulator checks which units a number uses before relying on it.

Common units in insulation work and their conversions.
QuantitySI unitUS customary unitConversion
Length, thicknessmm, min, ft25.4 mm = 1 in; 0.3048 m = 1 ft
Temperature reading°C°F°F = °C × 1.8 + 32
Temperature difference°C or K°F1 °C = 1.8 °F
EnergykJ, kWh, GJBtu, therm1 Btu ≈ 1.055 kJ; 1 kWh ≈ 3,412 Btu
Heat flowW, kWBtu/h1 W ≈ 3.412 Btu/h
Heat loss per lengthW/mBtu/h·ft1 W/m ≈ 1.04 Btu/h·ft
Thermal conductivityW/(m·K)Btu·in/(h·ft²·°F)1 Btu·in/(h·ft²·°F) ≈ 0.1442 W/(m·K)
Thermal resistanceRSI (m²·K/W)R (h·ft²·°F/Btu)RSI 1 ≈ R-5.678; R-1 ≈ RSI 0.176

Common mistakes

  • MistakeAdding 32 when converting a temperature difference.

    InsteadA difference converts by multiplying or dividing by 1.8 only.

  • MistakeUsing a k-value listed at the pipe temperature instead of the mean temperature.

    InsteadFind the mean of the inner and outer face temperatures and use the data sheet value for that mean.

  • MistakeConfusing kW with kWh, or Btu/h with Btu.

    InsteadkW and Btu/h are rates of heat flow; kWh and Btu are amounts of energy. Energy = rate × time.

  • MistakeTalking about cold flowing out of a cold line.

    InsteadHeat flows in from the warmer surroundings. Insulation on a cold line slows that heat gain.

  • MistakeAssuming every number on a data sheet uses the same units.

    InsteadRead the units beside every value. Many data sheets mix SI and US customary units.

Summary and key terms

  • Temperature measures how hot something is; heat is energy flowing because of a temperature difference.
  • Heat always flows from hot to cold, and a bigger temperature difference drives it faster.
  • Convert temperature readings with °F = °C × 1.8 + 32, but convert temperature differences by the factor 1.8 alone.
  • The mean temperature of insulation is the average of its inner and outer face temperatures.
  • Energy is measured in joules, kilowatt-hours, Btu and therms; heat flow in watts, Btu per hour and tons of refrigeration.
  • Sensible heat changes temperature (Q = m × c × ΔT); latent heat changes state at a constant temperature and is large.
  • Insulators in both countries work with both SI and US customary units, so always check the units of a number.
Temperature
A measure of how hot or cold something is.
Heat
Energy that flows from one place to another because of a temperature difference.
Absolute zero
The lowest possible temperature: 0 K, −273.15 °C or −459.67 °F.
Mean temperature
The average of the temperatures on the two faces of an insulation layer.
Btu
British thermal unit, about the heat needed to warm one pound of water by one degree Fahrenheit.
Ton of refrigeration
A rate of heat removal equal to 12,000 Btu/h, about 3.517 kW.
Specific heat
The heat needed to raise the temperature of one unit of mass of a material by one degree.
Latent heat
Heat absorbed or released when a material changes state without changing temperature.

Practice problems

Work each problem on paper first, then reveal the answer to check.

  1. Convert 120 °C to Fahrenheit.

    Show answer

    120 × 1.8 + 32 = 248 °F.

  2. A pipe is at 4 °C and the room at 24 °C. What is the difference in Fahrenheit degrees?

    Show answer

    20 °C × 1.8 = 36 °F.

  3. The insulation faces are at 150 °C and 30 °C. What is the mean temperature?

    Show answer

    (150 + 30) ÷ 2 = 90 °C.

  4. A pipe loses 2.5 kW for 400 hours. How much energy is that?

    Show answer

    2.5 × 400 = 1,000 kWh.

  5. How much heat raises 500 kg of water by 20 °C?

    Show answer

    500 × 4.19 × 20 = 41,900 kJ.

Lesson quiz · 5 questions

Score 60% or more to complete this lesson.

Take the quiz