Services, Distribution and Three-Phase Systems
Three-phase systems, large services and load calculations, switchboards and switchgear, overcurrent devices and trip units, short-circuit calculations, selective coordination and arc flash, distribution transformers, grounding and bonding, ground-fault protection and high-resistance grounding, feeders and power quality, medium-voltage systems, and testing, commissioning and maintenance.
ELEC-320 12 lessons · 4 h 56 min
Offered by HSM University · Electrician
This is the Canadian version of this course. See the American version.
What you'll learn
- Describe three-phase wye and delta systems used for services and distribution, and calculate voltages, currents and power in them
- Perform load calculations for large services and select service equipment, conductors and arrangements
- Compare switchboards, switchgear, panelboards and motor control centres and select them by rating and application
- Explain and apply fuses, molded-case and power circuit breakers, and LSIG electronic trip units
- Calculate available short-circuit current with the point-to-point method and verify equipment interrupting and withstand ratings
- Interpret time-current curves, achieve selective coordination, and explain arc flash studies, labels and mitigation
- Select, connect, protect, ground and test distribution transformers, including taps, inrush and harmonic loads
- Design grounding electrode systems and size grounding electrode conductors, bonding jumpers and equipment bonding conductors
- Apply ground-fault protection of equipment and compare solidly grounded, ungrounded and high-resistance grounded systems
- Size feeders and parallel conductors, calculate voltage drop, address harmonics and correct power factor
- Describe medium-voltage distribution, shielded cables, terminations, cable testing, protective relays and safe work practices
- Plan acceptance testing, energization, commissioning and maintenance of distribution systems
Course content
12 lessons · 4 h 56 min total · final exam
- 1 Three-phase systems for services and distribution 26 min · quiz
- 2 Large services and load calculations 24 min · quiz
- 3 Switchboards, switchgear, panelboards and motor control centres 24 min · quiz
- 4 Overcurrent protective devices: fuses, breakers and trip units 24 min · quiz
- 5 Short-circuit current calculations 24 min · quiz
- 6 Selective coordination and arc flash hazard 25 min · quiz
- 7 Transformers in distribution systems 24 min · quiz
- 8 Grounding and bonding for large services 25 min · quiz
- 9 Ground-fault protection and system grounding methods 25 min · quiz
- 10 Feeders, busway and power quality in distribution 26 min · quiz
- 11 Medium-voltage systems for large facilities 23 min · quiz
- 12 Testing, commissioning and maintenance of distribution systems 26 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
Three-phase systems, large services and load calculations, switchboards and switchgear, overcurrent devices and trip units, short-circuit calculations, selective coordination and arc flash, distribution transformers, grounding and bonding, ground-fault protection and high-resistance grounding, feeders and power quality, medium-voltage systems, and testing, commissioning and maintenance.