Canadian Electrical Code II
Commercial and industrial code requirements: feeders, wiring methods, motors, protection, grounding, hazardous locations, special systems, life safety and lighting.
ELEC-220 12 lessons · 6 h 16 min
Offered by HSM University · Electrician
This is the Canadian version of this course. See the American version.
What you'll learn
- Calculate commercial service and feeder loads under Rule 8-210 and Table 14, apply demand factors, voltage drop, taps and parallel conductors, and explain when ground fault protection is required
- Select commercial and industrial wiring methods and calculate conduit fill, bends, box fill, PVC expansion and support, cable tray and busway use, and firestopping
- Size motor branch circuit conductors, overload protection, short-circuit protection, disconnects and feeders for single and multiple motors and drives, and read three-wire control circuits
- Apply overcurrent device ratings, estimate available fault current, verify interrupting ratings and SCCRs, protect transformers and secondary conductors, and recognize arc flash requirements
- Classify hazardous locations by zone or division, group and temperature code, select protection methods and equipment markings, and apply sealing and intrinsic safety rules
- Ground and bond commercial and industrial systems, including services, separately derived systems, impedance grounding, bonding conductor sizing and grounding electrodes
- Apply the special rules for health care facilities, pools, electric vehicle charging, photovoltaic and storage systems, fire pumps and information technology rooms
- Apply requirements for industrial control panels, SCCR, enclosures and heat, PLC wiring, machine safety circuits and lockout
- Distinguish emergency, required standby and optional standby systems, and apply rules for sources, transfer switches, wiring separation, selective coordination, generator sizing and testing
- Install and verify fire alarm circuits, supervision, notification appliance voltage drop, batteries, Class 2 wiring, structured cabling and Power over Ethernet
- Design commercial lighting branch circuits, LED driver loading, dimming and energy-code lighting controls, and site and sign lighting
- Plan permits, inspections, pre-energization tests, commissioning and documentation, and prepare the electrical design of a small commercial building
Course content
12 lessons · 6 h 16 min total · final exam
- 1 Feeders and services 36 min · quiz
- 2 Commercial and industrial wiring methods 33 min · quiz
- 3 Motor circuits 35 min · quiz
- 4 Overcurrent protection, fault current and transformers 27 min · quiz
- 5 Hazardous locations 33 min · quiz
- 6 Grounding and bonding in commercial and industrial systems 31 min · quiz
- 7 Special occupancies and equipment 33 min · quiz
- 8 Industrial control panels and machinery 30 min · quiz
- 9 Emergency and standby systems 31 min · quiz
- 10 Fire alarm, communication and low-energy systems 29 min · quiz
- 11 Commercial lighting, controls and energy codes 30 min · quiz
- 12 Permits, inspection, testing and a commercial project 28 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
Commercial and industrial code requirements: feeders, wiring methods, motors, protection, grounding, hazardous locations, special systems, life safety and lighting.