Backup Power: UPS, Batteries and Generators
Keeping the load up when the utility fails.
DCE-340 Year 3 3 credits 12 lessons · 6 h 5 min
Offered by HSM University · Data Centre Engineering
This is the Canadian version of this course. See the American version.
What you'll learn
- Explain utility power disturbances and the ITIC curve, compare UPS topologies, and size UPS capacity, modules and bypass arrangements
- Compare utility service arrangements, interpret reliability statistics, and assess voltage sags, harmonics against IEEE 519 and large-load ride-through requirements
- Select and size lead-acid and lithium-ion batteries for UPS duty, and apply monitoring, ventilation and fire safety requirements
- Compare AC, −48 V, 380 V DC and high-voltage DC distribution, and size rack battery backup units and storage for smoothing AI power swings
- Rate and size diesel generators for data centre loads, plan fuel storage and testing, and explain emissions regulations
- Evaluate battery energy storage for peak shaving and grid services while preserving backup reserve, and compare on-site generation and microgrids
- Describe transfer switch types and sequences of operation, and explain synchronizing, load sharing and load shedding in paralleling switchgear
- Analyze fault current from utility, generator and UPS sources, and coordinate protection, grounding and arc flash across operating modes
- Compare N+1, 2N, distributed redundant and block redundant architectures and calculate loading and availability
- Plan commissioning from factory tests to integrated systems testing, and interpret battery capacity, load bank and transfer test results
- Apply maintenance strategies, monitoring, methods of procedure and emergency procedures to keep backup power reliable
- Design a backup power system for a mixed AI and conventional data hall, sizing generators, fuel, UPS and storage and assessing reliability and sustainability
Course content
12 lessons · 6 h 5 min total · final exam
- 1 UPS topologies 34 min · quiz
- 2 The utility supply and power quality 31 min · quiz
- 3 Batteries: lead-acid, lithium-ion and safety 33 min · quiz
- 4 DC power and rack-level energy storage 28 min · quiz
- 5 Generators, fuel and emissions 34 min · quiz
- 6 Battery energy storage, grid services and on-site generation 28 min · quiz
- 7 Transfer switches and paralleling 34 min · quiz
- 8 Protection and coordination with backup sources 29 min · quiz
- 9 Redundancy architectures: N+1, 2N, distributed and block 32 min · quiz
- 10 Testing and commissioning backup power 26 min · quiz
- 11 Operating and maintaining backup power 28 min · quiz
- 12 Designing a backup power system 28 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
Keeping the load up when the utility fails.
Part of the Engineering stream, typically taken in year 3.