ROOF-120 · Lesson 7 of 12 · 27 min

Membranes and plastics

▶ Video coming soon A video version of this lesson is on the way.

The Eastport Distribution warehouse roof is so big that Rory could not see the far parapet through the summer haze. Crew 2 was there for a service call: a forklift driver had punctured the white TPO membrane at a skylight while helping a contractor, and a seam near the loading docks had opened. Dana set down a hot-air welder, a silicone roller and a seam probe. "Rubber, plastic, it all looks the same from the ground," she said. "Up here, you'd better know which one you're standing on, because the repair is completely different."

Single-ply membranes, liquid-applied membranes and many other plastic and rubber products have changed roofing over the past 50 years. This lesson explains the main membrane families (EPDM, TPO and PVC), how their seams are made, how they are held down, what they can and cannot touch, and the other plastics roofers handle every day: vapor retarders, underlayments, tapes, sealants and skylights.

What single-ply means

A single-ply membrane is one factory-made sheet, laid in a single layer, that forms the whole waterproofing of a low-slope roof. Sheets are made in wide rolls (often 10 ft or wider) and joined on the roof with seams. Compared with built-up and mod-bit roofs, single-ply roofs are lighter, faster to install and need no kettles, and the white sheets reflect sunlight. Their weakness is that they have only one layer, so any puncture or bad seam is a leak, and they need careful protection from traffic and sharp objects.

Single-ply membranes fall into two chemical families, and the difference controls how they are seamed and repaired:

  • Thermosets are cured (vulcanized) during manufacture, like a car tire. Once cured, they cannot be melted or welded. Seams must be glued or taped. EPDM is the main thermoset roofing membrane.
  • Thermoplastics soften when heated and harden again when cooled, as many times as needed. Seams are joined by melting the two sheets together with hot air, forming a weld. TPO and PVC are the main thermoplastic membranes.
Two boxes compare thermoset EPDM, cured rubber that cannot be re-melted and is seamed with primer and seam tape, with thermoplastic TPO and PVC, which soften with heat and are joined by hot-air welding. Below, sketches show a tape seam with primer and tape in the lap, and a welded seam with a fused zone of plastic made by hot air.
Thermoset and thermoplastic membranes and their seams.

EPDM

EPDM (ethylene propylene diene monomer) is a synthetic rubber membrane, usually black, sometimes white. It has been used on roofs since the 1960s and has a long record of durability: it stays flexible in extreme cold, resists UV and ozone, and stretches several times its length before breaking. Common thicknesses are 45 mil and 60 mil, and it comes in very large sheets, which means fewer seams. It is made to ASTM D4637.

EPDM seams are made by cleaning and priming both surfaces, then pressing a strip of factory-made seam tape (a cured or semi-cured rubber adhesive tape) into the lap and rolling it firmly. Older roofs used liquid splice adhesive. The common causes of EPDM seam failure are dirty or unprimed laps, too little rolling pressure, and fish-mouths (wrinkles at the seam edge). EPDM does not tolerate oils, greases, solvents and petroleum products: they swell and soften it. Keep it away from kitchen exhaust grease, and never use asphalt products on it unless the manufacturer approves them.

TPO

TPO (thermoplastic polyolefin) is a white or light-colored membrane with a polyester reinforcing scrim in the middle. It became popular in the 1990s and is now one of the most common commercial roof membranes. TPO has no added liquid plasticizers, so it does not shrink or become brittle from losing them, and its white surface reflects much of the sun's heat. Common thicknesses are 45, 60 and 80 mil. It is made to ASTM D6878.

The thickness that matters most is the part above the scrim, because that is the layer that wears away in the weather. Two membranes with the same total thickness can have different thicknesses over the scrim; the product data sheet tells you which is which. TPO seams are hot-air welded. Old, weathered TPO can be hard to weld because its surface has oxidized; it must be cleaned and sometimes scrubbed or treated with a special cleaner before a repair weld will hold, and repairs on very old TPO may need a different method approved by the manufacturer.

PVC

PVC (polyvinyl chloride) membranes are also thermoplastic and hot-air welded, and they have been used on roofs longer than TPO. Pure PVC is stiff, so roofing PVC contains plasticizers that make it flexible. PVC resists fire, grease, oils and many chemicals well, which makes it a common choice for restaurants and industrial roofs with exhaust fans. It is made to ASTM D4434.

PVC's weak point is its plasticizer. If PVC touches asphalt, polystyrene insulation or some other plastics, the plasticizer can migrate out of the membrane, leaving it brittle and shrunken. PVC must be separated from those materials with a slip sheet or a compatible cover board. Even on its own, over many years the plasticizer slowly leaves, so very old PVC can shatter when bent in cold weather.

Main single-ply membranes compared (general; the manufacturer's data rules).
PropertyEPDMTPOPVC
Familythermoset rubberthermoplasticthermoplastic
Usual colorblack (white available)white or lightwhite, gray or tan
Seamsprimer and seam tapehot-air weldedhot-air welded
Cold flexibilityexcellentgoodgood when new; stiffens with age
Grease and oil resistancepoorfairgood
Contact with asphaltonly if approvedonly if approvednever without a separator
Contact with polystyreneacceptableacceptable with approved boardneeds a separator

Welding thermoplastic seams

A hot-air weld is made by blowing air hot enough to melt the surfaces of both sheets into the lap, then pressing them together with a roller so they fuse into one piece. Large flat seams are welded with a wheeled automatic (robotic) welder; details and repairs are welded with a hand welder and a silicone roller. A good weld depends on three settings working together: temperature, speed and pressure. Weather changes the right settings: a cold, windy day needs more heat or less speed than a hot, still one.

That is why welding crews follow a routine:

  • Clean the seam area. Dirt, dust, water and old coatings all prevent fusion.
  • Make test welds on scrap at the start of every day, after breaks and whenever the weather changes. Let them cool, then peel them apart by hand. A good weld tears the membrane itself or pulls the scrim out, rather than peeling apart cleanly at the joint.
  • Weld the seam, keeping an even width. Many manufacturers require a continuous weld at least 1-1/2 in wide on automatic welded seams.
  • Once the seam has cooled, probe every welded seam by running a blunt probe, such as a cotter-pin puller, along the edge with firm pressure. The probe will slip into any gap. Mark and repair every void the same day.
  • Seal cut edges of reinforced sheets where the manufacturer requires it, so the scrim does not wick water.

Overheating is as bad as underheating. A burned weld is brittle and can crack beside the joint, and too much heat can scorch or thin the membrane. The welder should leave a small, even bead of melted material squeezed out along the seam edge.

Worked problem

How long will the seams take?

Glen is pricing a future replacement of the Eastport roof: 97,000 ft² of TPO in 10 ft wide rolls, lapped 6 in at the side seams. About how many feet of side seam will there be, and how long would a robotic welder running at 10 ft per minute take to weld them?

Show solution
  1. Each sheet covers a strip 10 − 0.5 = 9.5 ft wide.
  2. Total seam length ≈ area ÷ strip width = 97,000 ÷ 9.5 ≈ 10,211 ft.
  3. Welding time = 10,211 ÷ 10 ≈ 1,021 minutes.
  4. In hours: 1,021 ÷ 60 ≈ 17.0 hours of actual welding.

Answer: About 17 hours of welding on the field seams alone, before end laps, flashings and details, which are slower hand work. Wider sheets mean fewer seams, which is one reason wide rolls are popular.

Worked problem

How many rolls?

For the same estimate, each roll is 10 ft × 100 ft, lapped 6 in at the side seams. Ignoring end laps and flashings, how many rolls cover 97,000 ft²?

Show solution
  1. Coverage per roll = 9.5 ft × 100 ft = 950 ft².
  2. Rolls = 97,000 ÷ 950 ≈ 102.1, so 103 rolls.

Answer: 103 rolls for the field, plus perimeter half sheets, flashings and waste.

Holding single-ply membranes down

Single-ply membranes are attached in one of three main ways, chosen by the designer from the manufacturer's tested systems:

  • Mechanically attached: the sheet is fastened through the lap at each side seam with screws and plates into the deck, and the next sheet laps over and is welded or taped to cover the fasteners. It is quick and light, but the sheet between seams can flutter and billow in wind, which is why fastener spacing and sheet width are set by the wind design. A newer method, induction welding, fastens plates through the insulation first and then bonds the membrane to the tops of the plates with a magnetic heating tool, so there is no fastener row in the seam.
  • Fully adhered: the sheet is glued to the insulation or cover board with bonding adhesive (a contact adhesive applied to both surfaces) or with low-rise foam or other adhesives. Adhered roofs do not flutter and resist wind well, but cost more and depend on good adhesion to a sound substrate.
  • Ballasted: the sheet is laid loose and held down by the weight of river stone or concrete pavers, typically around 10 lb/ft² or more. Ballasted roofs are fast to install and easy to take apart, but the structure must carry the weight, the stones are hard to work around when finding leaks, and the edges and corners need extra ballast or pavers.

Worked problem

The weight of ballast

A 6,500 ft² EPDM roof on a school wing is to be ballasted with stone at 10 lb/ft². What is the total weight of the ballast?

Show solution
  1. Weight = 6,500 × 10 = 65,000 lb.
  2. That is 32.5 tons, spread at 10 lb/ft².

Answer: About 65,000 lb (32.5 tons). The structure must be checked to carry it, which is why a ballasted roof cannot simply be added to a building designed for a light roof.

Liquid-applied membranes and coatings

Some waterproofing is applied as a liquid that cures into a seamless membrane. Liquid-applied systems are especially good at details with complicated shapes, such as clusters of pipes, odd-shaped curbs and drains, where cutting and welding sheets would be awkward.

  • Reinforced liquid membranes: resins such as polymethyl methacrylate (PMMA), polyurethane or rubberized asphalt, applied in coats with a polyester fleece embedded between them. PMMA cures in less than an hour, even in cold weather, which makes it popular for flashings.
  • Roof coatings: acrylic, silicone, polyurethane or asphalt-based coatings applied over an existing, sound roof to restore its surface, reflect sunlight or extend its life. A coating is not a fix for a wet or failing roof; the substrate must be dry, sound and clean, and wet insulation must be replaced first.
  • Spray polyurethane foam roofs: foam insulation sprayed on the deck, which cures into a seamless, sloped surface and is then protected from UV with a coating.

Liquid systems are only as good as their surface preparation and their thickness. Each coat must reach the wet thickness the manufacturer specifies, which crews check with a wet-film gauge as they go. Temperature, humidity and dew all affect curing.

Other plastics on the roof

Roofers handle many other plastic and rubber products:

Plastics and rubbers used in roofing.
ProductTypical materialWhat to know
Vapor retarder sheetpolyethylene, about 6 milseal every lap and penetration; UV breaks it down if left exposed
Synthetic underlaymentwoven or spun polypropylenelight and strong; follow the maker's fastening and exposure limits
Self-adhered membranes and tapesrubberized asphalt or butylneed clean, dry, primed surfaces and minimum temperatures
Pipe boots and vent flashingsEPDM, TPO, PVC or plasticmatch the boot to the membrane; rubber boots crack in UV over time
Skylight domesacrylic or polycarbonateare not walkable; guard or screen them as in ROOF-110
Sealantspolyurethane, silicone, hybrid polymer, butylnot interchangeable; check compatibility with the membrane
Walkway padsrubber or the same thermoplastic as the membraneprotect the membrane on service routes

Sealants deserve a closer look because they are so often misused. A sealant joint works only if it sticks to two sides and can stretch freely. A bead that sticks to three sides (two sides and the back of the joint) tears when the joint moves. Proper joints have a foam backer rod to control depth and stop three-sided adhesion, and a depth about half the width. Silicone and polyurethane sealants are not compatible with each other, and silicone cannot be painted or covered by most other sealants later. Above all, sealant is a maintenance item: exposed sealants need checking and redoing every few years.

Compatibility: what can touch what

Many membrane failures come from two materials that should never have met. Before any repair or tie-in, identify the existing membrane and check the manufacturer's compatibility list. The common incompatibilities are:

  • PVC with asphalt, coal tar, polystyrene and some other plastics: plasticizer migration.
  • EPDM with oils, greases, solvents and most asphalt products: swelling and softening.
  • Polystyrene insulation with solvent-based adhesives, primers and sealants: the foam dissolves.
  • TPO with PVC: they will not weld to each other.
  • Silicone with almost everything that comes after it: nothing sticks to cured silicone except more silicone.

If you are not sure what a membrane is, there are clues. EPDM feels rubbery, stretches easily and has taped or glued seams. TPO and PVC have welded seams with a small bead at the edge. PVC is usually more supple and has a slight smell when heated; TPO feels slightly waxy. A small sample sent to the manufacturer or a lab settles any doubt. Dana's rule for the crew is simple: no repair until you know what you are repairing.

The Harbourside repair

At the skylight, Dana cleaned a wide area around the puncture, scrubbed the weathered TPO with the manufacturer's cleaner, made two test welds on scrap and peeled them, then welded a rounded patch over the hole with a hand welder and roller. The open seam near the docks had never been fully welded; she cut out the bad section, cleaned it and welded a cover strip over it, then had Rory probe every inch of the repair once it had cooled. "Round corners on every patch," she said. "Square corners lift. And probe it all, every time."

Common mistakes

  • MistakeUsing asphalt cement to patch EPDM or PVC.

    InsteadIdentify the membrane and use the manufacturer's compatible repair method: tape and primer on EPDM, hot-air weld on TPO and PVC.

  • MistakeSkipping test welds because the welder worked yesterday.

    InsteadMake and peel test welds at the start of each day, after breaks and when the weather changes.

  • MistakeWelding a seam and never probing it.

    InsteadProbe every welded seam once it cools and repair every void.

  • MistakeLaying PVC directly on old asphalt or polystyrene.

    InsteadInstall a separator or compatible cover board to stop plasticizer migration.

  • MistakeTreating sealant as a permanent repair.

    InsteadUse proper flashings; design sealant joints with a backer rod and inspect them regularly.

Summary and key terms

  • Single-ply roofs use one factory-made sheet, joined with seams, as the whole waterproofing.
  • Thermosets such as EPDM are taped or glued; thermoplastics such as TPO and PVC are hot-air welded.
  • EPDM is flexible rubber that hates oils; TPO is reflective with no added plasticizer; PVC resists grease but loses plasticizer and must be separated from asphalt and polystyrene.
  • Welds depend on temperature, speed and pressure; test-weld daily and probe every seam.
  • Membranes are mechanically attached, fully adhered or ballasted, as tested by the manufacturer and set by the wind design.
  • Liquid-applied membranes suit complex details; coatings need a sound, dry roof.
  • Check compatibility before every repair or tie-in.
Single-ply membrane
A single factory-made sheet that forms the whole waterproofing of a roof.
Thermoset
A material cured during manufacture that cannot be re-melted, such as EPDM.
Thermoplastic
A material that softens with heat and hardens when cooled, such as TPO and PVC.
Scrim
The reinforcing fabric inside a membrane.
Plasticizer
An additive that makes PVC flexible.
Test weld
A sample weld made on scrap and peeled apart to check the welder settings.
Ballast
Stone or pavers whose weight holds a loose-laid membrane in place.
Backer rod
A foam rod placed in a joint to control sealant depth and prevent three-sided adhesion.

Practice problems

Work each problem on paper first, then reveal the answer to check.

  1. How are EPDM seams usually made?

    Show answer

    By cleaning and priming the lap and applying seam tape, then rolling it firmly.

  2. Convert 60 mil to millimeters.

    Show answer

    60 × 0.0254 ≈ 1.52 mm.

  3. What does a good peel test on a weld look like?

    Show answer

    The membrane tears or the scrim pulls out instead of the weld peeling apart cleanly.

  4. A 4,000 ft² roof is ballasted at 12 lb/ft². What does the ballast weigh?

    Show answer

    48,000 lb, or 24 tons.

  5. Why must PVC be kept off asphalt?

    Show answer

    Plasticizer migrates out of the PVC, leaving it brittle and shrunken.

Lesson quiz · 5 questions

Score 60% or more to complete this lesson.

Take the quiz