Plumbing math and science review

Math and science questions are scattered through every part of the exam. A drainage question needs the fall over a run; a water supply question needs the pressure at a height; a hydronic question needs heat and flow; a pipe preparation question needs an offset length; a water heater question needs a temperature rise. None of these is hard on its own, but each one can be lost to a units mistake or a slip under time pressure, and together they add up to a large share of the marks.

Maya was good at math in school, and she was surprised how many practice questions she got wrong anyway. Her error log showed the pattern: almost every mistake was a units mistake, a wrong constant or an answer she did not check against common sense. Luis's cure was a one-page formula sheet that she wrote herself, a set of quick sanity checks, and a daily drill of five mixed calculations.

Units and conversions

Canadian plumbing work is metric, but many products, threads and older drawings are in inches, and many tradespeople still think in feet and pounds per square inch. The exam is in metric units, with imperial sizes where the trade uses them, such as nominal pipe sizes. Knowing a handful of conversions well beats knowing many vaguely.

The conversions worth knowing by heart.
QuantityConversionUse
Length1 in = 25.4 mm; 1 ft = 0.3048 mPipe lengths, offsets, drawing scales
Volume1 US gal = 3.785 L; 1 ft³ = 7.48 US gal; 1 m³ = 1000 LTanks, pipes, water use
Pressure1 psi = 6.895 kPa; 1 bar = 100 kPaTest pressures, PRV settings
Pressure from height9.81 kPa per m of water; 0.433 psi per ftElevation loss, static head
Energy and power1 kW = 3412 Btu/h; 1 kWh = 3.6 MJHeaters, boilers, gas loads
Temperature°F = 1.8 × °C + 32; a difference of 1 °C = 1.8 °FTemperature rise, mixing
Flow1 L/s = 15.85 US gpmPumps, demand, storm

The temperature line has a trap. Converting a temperature uses the full formula with the 32; converting a temperature difference uses only the 1.8. A rise of 50 °C is a rise of 90 °F, not 122 °F. Exam questions about water heater recovery and hydronic temperature drops depend on this.

The best protection against units errors is to carry the units through every line of a calculation and cancel them like numbers. If the units at the end are not the units of the answer, the calculation is wrong somewhere, and the units show where.

Area and volume

Pipe and tank volumes appear in questions about test water, flushing, disinfection and storage. The internal volume of a pipe is its cross-sectional area times its length. A handy shortcut in metric: a pipe of internal diameter d in millimetres holds about d squared divided by 1273 litres per metre, because the area in square millimetres is pi d squared over 4, and a metre of pipe holds one millilitre for every square millimetre of area.

Worked problem

Water needed to disinfect a new main

A new 150 mm water main, internal diameter 155 mm, is 120 m long. It is to be filled with a chlorine solution. How many litres does it hold?

Show solution
  1. \[\text{per metre} = \frac{155^2}{1273} \approx 18.9\ \text{L/m}\]
  2. \[V = 18.9 \times 120 \approx 2260\ \text{L}\]

Answer: The main holds about 2,260 L, a little over two cubic metres. A sanity check: a 150 mm pipe is about the size of a large paint can across, and 120 m of it is a lot of water, so a few thousand litres is reasonable; 22 L or 226,000 L would not be.

Rectangular tanks are length times width times depth. Cylindrical tanks are the area of the circle times the height. A cylinder lying on its side, like many oil and propane tanks, is harder to calculate partly full, and exam questions on it usually give a chart.

Pressure, head and the atmosphere

Water pressure from height is the most used piece of science in plumbing. A column of water 1 m high exerts about 9.81 kPa at its base, whatever the shape or size of the pipe. This is why the pressure at the bottom of a tall riser is so much higher than at the top, and why a test with a water column 3 m high applies about 29 kPa to the joints at the bottom.

Atmospheric pressure at sea level is about 101 kPa, which can support a column of water about 10.3 m high. That number limits suction lift: no pump can lift water by suction more than about 10 m in theory, and much less in practice, because of friction, vapour pressure and the pump's own needs. It also explains siphons, which work only while the high point is less than that height above the supply surface, and it explains why trap seals can be pulled out by the small pressure differences that venting is designed to prevent.

Gauge pressure is measured relative to the atmosphere; absolute pressure includes it. A gauge reading 300 kPa means 401 kPa absolute. Use absolute pressure whenever a gas is involved: expansion tanks, air chambers, compressed air tests. Use gauge pressure for everything else.

Offsets, angles and grade

Offsets with fittings are a pipe preparation topic, and they appear on the exam as calculations. A rolling or simple offset moves a line sideways by a set distance, the offset, using two fittings at the same angle. The length of pipe between the fittings, measured centre to centre, is the travel. Travel equals the offset times a constant that depends on the fitting angle, the cosecant of the angle.

Offset constants for common fitting angles.
Fitting angleTravel = offset ×Run = offset ×
22-1/2°2.6132.414
45°1.4141.000
60°1.1550.577
11-1/4°5.1265.027
A right triangle formed by a pipe offset. The vertical side is the offset, the horizontal side is the run, and the diagonal is the travel through two 45 degree fittings. A small inset shows a rolling offset in three dimensions, where the true offset is the diagonal of a rectangle formed by the vertical and horizontal displacements.
An offset triangle. For a rolling offset, find the true offset first with the Pythagorean theorem.

Worked problem

A rolling offset

A drain must move 300 mm to the side and 400 mm up while it travels along a wall, using two 45° fittings. What is the true offset, the travel and the run? How much pipe is cut if each fitting takes up 25 mm?

Show solution
  1. \[\text{true offset} = \sqrt{300^2 + 400^2} = 500\ \text{mm}\]
  2. \[\text{travel} = 1.414 \times 500 = 707\ \text{mm}, \quad \text{run} = 1.000 \times 500 = 500\ \text{mm}\]
  3. \[\text{cut} = 707 - 2 \times 25 = 657\ \text{mm}\]

Answer: The true offset is 500 mm, the travel 707 mm, and the pipe is cut to 657 mm centre to centre less the fitting take-offs.

Grade, the slope of a drain, is the fall divided by the run. A slope of 1 in 50 falls 20 mm in every metre, or 2 per cent; 1 in 100 falls 10 mm per metre, or 1 per cent. The fall over a run is the run times the slope. A 15 m building drain at 1 in 50 falls 300 mm, which decides whether it can reach the sewer connection at the depth available.

Heat, expansion and materials

Pipes grow when they get warm. The change in length is the original length times the coefficient of expansion times the temperature change. Plastic pipe expands several times as much as metal: PVC and CPVC move roughly 0.05 to 0.07 mm per metre per degree Celsius, copper about 0.017. A 30 m run of CPVC hot water pipe heated by 50 degrees grows by about 90 mm to 100 mm, which is why long plastic runs need expansion loops, offsets or compensators, and why hangers must let them move.

Heat calculations follow the same pattern as the hydronic and water heater lessons: heat equals mass times specific heat times temperature change. Latent heat, the heat taken in or given out when water changes state, is much larger: melting ice and boiling water both absorb a great deal of heat at a constant temperature. That is why steam carries so much heat, and why a frozen pipe takes so long to thaw.

Two pieces of chemistry also appear. Galvanic corrosion happens when two different metals are joined in water; the less noble metal, such as steel or zinc next to copper, corrodes. Dielectric unions or fittings break the electrical path. And pH measures acidity: water below about 7 is acidic and attacks copper and cement, while condensate from high-efficiency appliances is acidic enough to need neutralizing before it enters some drains.

Sanity checks

Under time pressure, a quick check catches more errors than recalculating. Maya used four checks on every calculation question.

  • Size: is the answer the right order of magnitude? A house does not use 50,000 L of water a day, and a residential water service does not carry 20 L/s.
  • Units: do the units at the end match the units the question asks for?
  • Direction: does the answer move the right way? A larger pipe should lose less pressure; a colder inlet should need more heat.
  • Options: if your answer is between two options, recheck the step where a factor of 2, 10 or 1.8 could have slipped in, because distractors are built from those slips.

A mixed math drill

Maya's drill program prints five random calculations with their answers hidden at the bottom, using a fixed seed so that the same drill can be repeated. Changing the seed gives a new drill.

# Mixed plumbing math drill: questions first, answers at the end
import math, random
random.seed(410)
qs = []
off = random.choice([200, 300, 450, 600])
qs.append((f"Two 45 degree fittings make a {off} mm offset. Travel?", f"{1.414 * off:.0f} mm"))
run, slope = random.choice([(12, 50), (18, 100), (25, 50)])
qs.append((f"A {run} m drain at 1 in {slope}. Fall?", f"{run * 1000 / slope:.0f} mm"))
h = random.choice([6, 9, 14, 22])
qs.append((f"Static pressure lost lifting water {h} m?", f"{h * 9.81:.1f} kPa"))
d, L = random.choice([(26.0, 40), (32.1, 25), (50.4, 60)])
qs.append((f"Volume of {L} m of pipe, internal diameter {d} mm?", f"{d ** 2 / 1273 * L:.1f} L"))
kw, rise = random.choice([(9, 45), (12, 50), (18, 40)])
qs.append((f"Recovery of a {kw} kW electric heater at a {rise} C rise?", f"{kw * 3600 / (4.19 * rise):.0f} L/h"))
for i, (q, a) in enumerate(qs, 1):
    print(f"{i}. {q}")
print()
for i, (q, a) in enumerate(qs, 1):
    print(f"Answer {i}: {a}")
Output
1. Two 45 degree fittings make a 300 mm offset. Travel?
2. A 25 m drain at 1 in 50. Fall?
3. Static pressure lost lifting water 14 m?
4. Volume of 40 m of pipe, internal diameter 26.0 mm?
5. Recovery of a 18 kW electric heater at a 40 C rise?

Answer 1: 424 mm
Answer 2: 500 mm
Answer 3: 137.3 kPa
Answer 4: 21.2 L
Answer 5: 387 L/h

Try working the five questions on paper before scrolling to the answers, then change the seed and repeat. Five a day for six weeks is two hundred calculations, and by then the constants are automatic.

Levers, pulleys and sling angles

Rigging questions in the common occupational skills area are math questions in disguise. A lever balances when the load times its distance from the pivot equals the effort times its distance, so a pry bar with the pivot close to the load multiplies the effort. A block and tackle has a mechanical advantage equal to the number of rope parts supporting the moving block, less friction losses, so a four-part tackle lifts a load with about a quarter of the pull but needs four times the rope to be pulled through.

Sling angles matter even more, because they change the load in each leg. When two sling legs lift a load, the tension in each leg is half the load divided by the sine of the angle between the leg and the horizontal. At 60 degrees, each leg of a two-leg sling carries about 58 per cent of the load; at 45 degrees, about 71 per cent; at 30 degrees, a full 100 per cent. A water heater of 150 kg lifted on a two-leg sling at 30 degrees puts about 150 kg in each leg, the same as if one leg carried it alone.

\[T_{\text{leg}} = \frac{W}{2 \sin \theta} \qquad \theta = 30^\circ \to T = \frac{W}{2 \times 0.5} = W\]

The practical rule follows: keep sling angles at 45 degrees or steeper from the horizontal, and never below 30, and check the rated capacity of the sling at the angle being used, not its vertical rating. An exam question that gives a load, a sling angle and a sling rating is testing whether you apply the angle before comparing.

Common mistakes

  • MistakeUsing the full temperature formula for a temperature difference.

    InsteadA difference of 1 °C is 1.8 °F; the 32 applies only to temperatures.

  • MistakeUsing gauge pressure in a gas law problem.

    InsteadAdd about 101 kPa to get absolute pressure.

  • MistakeUsing the side or vertical displacement as the offset in a rolling offset.

    InsteadFind the true offset with the Pythagorean theorem first.

  • MistakeCutting pipe to the travel length.

    InsteadSubtract the fitting take-offs from the centre-to-centre travel.

  • MistakeAccepting an answer without a sanity check.

    InsteadCheck size, units, direction and the factors that distractors are built from.

Summary and key terms

  • Carry units through every calculation; most math errors on the exam are units errors.
  • Pressure from height is about 9.81 kPa per metre of water; the atmosphere supports about 10.3 m.
  • Use absolute pressure whenever a gas is involved; gauge pressure otherwise.
  • Travel equals offset times the fitting constant, 1.414 for 45°; find the true offset of a rolling offset first.
  • Expansion equals length times coefficient times temperature change; plastic moves several times as much as copper.
  • Check every answer for size, units, direction and the common factor slips.
Travel
The centre-to-centre length of pipe between two offset fittings.
True offset
The straight-line displacement of a rolling offset, from both of its components.
Gauge pressure
Pressure measured relative to the atmosphere.
Absolute pressure
Gauge pressure plus atmospheric pressure.
Coefficient of expansion
The change in length per unit length per degree of temperature change.

Practice problems

Work each problem on paper first, then reveal the answer to check.

  1. Convert a temperature rise of 40 °C to °F.

    Show answer

    72 °F.

  2. What pressure does a 3 m water test apply at its base?

    Show answer

    About 29.4 kPa.

  3. Two 22-1/2° fittings make a 250 mm offset. What is the travel?

    Show answer

    2.613 × 250, about 653 mm.

  4. How much does a 20 m drain at 1 in 50 fall?

    Show answer

    400 mm.

  5. A gauge reads 200 kPa. What is the absolute pressure?

    Show answer

    About 301 kPa.

Lesson quiz · 5 questions

Score 60% or more to complete this lesson.

Take the quiz