CIV-331 · Lesson 1 of 12 · 23 min

Steel structures and limit states design

Steel frames carry most of the industrial buildings, warehouses, arenas and tall office towers built in Canada. This course teaches you to design the members and connections of those frames to CSA S16, Design of steel structures, with loads from the National Building Code of Canada (NBC). The first lesson sets the stage: why steel behaves the way it does, how steel buildings are organized, how limit states design puts safety into the numbers, and what the Kestrel Bay team will design in the steel-framed maintenance bay of the Thunder Bay operations centre.

Why build in steel

Structural steel is strong for its weight. A rolled beam can span three times as far as a timber joist of the same depth, and a steel column occupies a fraction of the floor area of a concrete column carrying the same load. Steel is also ductile: a steel member that is overloaded yields, stretches and bends visibly long before it breaks, which gives warning and lets loads shift to other parts of the structure. Ductility is the main reason steel frames perform well in earthquakes and survive local damage.

Steel members are made in a shop and erected on site. Shapes come from the mill in standard sizes, the fabricator cuts, drills and welds them, and the erector bolts them together, often in all weather. A steel frame can go up in weeks, and it can be modified later: a beam can be reinforced, a new opening framed or a mezzanine added. At the end of a building's life steel is recycled, and most structural shapes made in North America already contain a large share of recycled scrap from electric arc furnaces.

Steel has weaknesses that the designer must manage:

  • Slender members and thin plates buckle. Because steel is so strong, members are slender, and stability rather than strength often controls design. Much of this course is about buckling of columns, beams and plates.
  • Steel loses strength and stiffness at high temperature, so buildings that need a fire-resistance rating protect the steel with sprayed materials, boards, intumescent coatings or concrete encasement.
  • Unprotected steel corrodes in wet or salty environments. Paint, galvanizing and detailing that sheds water control corrosion.
  • Repeated stress cycles, such as those from a crane, can grow cracks at welds and holes. This is fatigue.
  • At low temperatures, thick plates with notches or cracks can fail in a brittle way. Material toughness requirements and good detailing prevent this, which matters in an unheated building in a northern city.

How steel buildings are organized

Most steel buildings are assembled from a small set of members. Beams carry floor and roof loads in bending; girders are larger beams that carry other beams. Columns carry the beam reactions down to the foundations. Long roof spans use trusses or open-web steel joists, and a profiled steel deck spans between joists or beams, either bare on a roof or filled with concrete on a floor.

The frame must also resist lateral loads from wind and earthquakes and keep the columns from swaying. There are two main ways to do this. In a braced frame, diagonal members form vertical trusses in some bays, and the beams are connected to the columns with simple connections that transfer shear but little moment. In a moment frame, rigid beam-to-column connections make the beams and columns act together in bending. Braced frames use less steel; moment frames keep bays open for doors and windows. Many buildings use both, with braces in one direction and moment frames in the other.

Connections decide how the frame behaves. A simple shear connection, such as a pair of angles bolted to the beam web, lets the beam end rotate and is modelled as a pin. A moment connection, with the beam flanges welded or bolted to the column, is modelled as rigid. The designer chooses the connection type at the start, because the analysis model, member sizes and cost all depend on it.

An isometric sketch of the maintenance bay: six-panel Pratt roof trusses spanning 18 m (60 ft) between wall columns, X-bracing in one wall bay, a monorail hoist beam under the roof, and a mezzanine with beams at 3 m (10 ft) spacing framing into edge girders and interior columns.
The steel-framed maintenance bay and the members designed in this course.

Steel design standards

In Canada, the NBC sets the loads and the performance requirements, and its structural part refers to CSA S16 for the design of steel members and connections. S16 is updated on a cycle of about five years; the current edition is S16:24, while provincial codes based on the 2020 NBC refer to S16-19. The design provisions used in this course have been stable across recent editions. Other standards fill in the details: CSA G40.21 for structural steel, CSA W59 for welded construction, CSA W47.1 for certification of welding companies, and ASTM standards for bolts and many rolled shapes. The Canadian Institute of Steel Construction (CISC) publishes the Handbook of Steel Construction, with section properties, design tables and the text of S16 with commentary. You will use its tables constantly.

Limit states design

A limit state is a condition in which a structure or member stops doing its job. Ultimate limit states involve collapse or failure: yielding over a whole cross-section, fracture at a bolt hole, buckling of a column, failure of a weld. Serviceability limit states involve fitness for use: deflection that cracks partitions, floor vibration that annoys occupants, or drift that damages cladding.

S16 uses limit states design. For every ultimate limit state, the factored resistance must be at least the effect of the factored loads:

\[\phi R \ \ge\ \text{effect of } \textstyle\sum \alpha_i S_i\]

Here \(R\) is the nominal resistance computed from specified material strengths and nominal dimensions, \(\phi\) is a resistance factor less than 1.0 that accounts for variability in material, dimensions and workmanship and for the consequences of failure, and the \(\alpha_i\) are load factors that account for loads larger than specified. In S16 the symbol for a factored resistance carries a subscript r: \(T_r\), \(C_r\), \(M_r\), \(V_r\). Factored load effects carry a subscript f: \(T_f\), \(C_f\), \(M_f\), \(V_f\).

The resistance factors reflect how predictable each limit state is and how serious its failure would be. Yielding of steel is predictable and ductile, so it gets a high factor. Fracture through a net section or a weld is less predictable and gives no warning, so its factor is lower.

Typical resistance factors used in this course.
Limit stateS16 factor
Yielding of a gross section, member buckling, bendingφ = 0.90
Fracture of a net section, block shearφu = 0.75
Shear yielding of a rolled beam webφ = 0.90
Bolts in shear or tensionφb = 0.80
Bearing of bolts on connected materialφbr = 0.80
Fillet weldsφw = 0.67

Load combinations

The NBC gives five principal load cases for ultimate limit states. Each combines one principal load with companion loads, and dead load is factored by 1.25, or by 0.9 when it reduces the effect being checked:

NBC load cases for the ultimate limit states (simplified; some occupancies use other companion factors).
CasePrincipal loadsCompanion loads
11.4D—
2(1.25D or 0.9D) + 1.5L1.0S or 0.4W
3(1.25D or 0.9D) + 1.5S1.0L or 0.4W
4(1.25D or 0.9D) + 1.4W0.5L or 0.5S
51.0D + 1.0E0.5L + 0.25S

Serviceability is checked with specified (unfactored) loads, usually the live load alone for deflection of floors, or dead plus live for total deflection.

The maintenance bay

The Kestrel Bay team of Priya Raman (project lead), Owen Lachance (EIT) and Sofia Martel (co-op student) designed the reinforced concrete office wing in CIV-330. The garage includes a steel-framed maintenance bay, 18 m wide, with a mezzanine for parts storage, a monorail hoist for lifting engines, and Pratt roof trusses that you analysed in CIV-224. This course designs its steel: the truss chords, the mezzanine beams, girders and columns, a wall column, the bracing, the monorail, and the bolted and welded connections that join them.

The mezzanine is a concrete slab on steel deck. Beams at 3.0 m centres span 9.0 m between edge girders, and the girders span 9.0 m between columns, so each girder carries two beam reactions at its third points. The slab, deck and services weigh 3.0 kPa, and the storage live load is 4.8 kPa.

Worked problem

Design loads for a mezzanine beam

Find the factored moment and shear for a typical mezzanine beam: span 9.0 m, spacing 3.0 m, dead load 3.0 kPa plus an assumed self-weight of 0.65 kN/m, live load 4.8 kPa.

Show solution
  1. Line loads on the beam:
  2. \[w_D = 3.0(3.0) + 0.65 = 9.65\ \text{kN/m} \qquad w_L = 4.8(3.0) = 14.4\ \text{kN/m}\]
  3. Case 1 gives \(1.4(9.65) = 13.5\) kN/m. Case 2, with live load as the principal load, governs:
  4. \[w_f = 1.25(9.65) + 1.5(14.4) = 33.7\ \text{kN/m}\]
  5. \[M_f = \frac{w_f L^2}{8} = \frac{33.7(9.0)^2}{8} = 341\ \text{kN·m} \qquad V_f = \frac{w_f L}{2} = 152\ \text{kN}\]

Answer: \(M_f = 341\) kN·m and \(V_f = 152\) kN. Lesson 5 selects the beam.

Worked problem

Girder and truss chord forces

Find the factored moment in an edge girder that carries the reactions of two beams at its third points, and the governing chord forces in the roof truss of CIV-224 (18 m span, six 3 m panels, 2.0 m deep, dead load 7.7 kN/m and snow 19.7 kN/m along the truss).

Show solution
  1. Girder: each beam delivers \(P = 152\) kN, and between the third points the moment is constant:
  2. \[M_f = P\,\frac{L}{3} = 151.5(3.0) = 454\ \text{kN·m} \quad \text{plus the girder self-weight}\]
  3. Truss: case 3 with snow as the principal load gives \(w_f = 1.25(7.7) + 1.5(19.7) = 39.2\) kN/m and panel loads \(P = 117.5\) kN. From the method of sections in CIV-224:
  4. \[T_{L2L3} = \frac{M_{U2}}{h} = 705\ \text{kN (tension)} \qquad C_{U2U3} = \frac{M_{L3}}{h} = 793\ \text{kN (compression)}\]

Answer: The girder moment is 454 kN·m before self-weight; the bottom chord carries 705 kN in tension and the top chord 793 kN in compression. Lessons 3 and 6 use these forces.

Sofia keeps the load calculations in a short program so that every later lesson starts from the same numbers. If the storage load or the snow load changes, she reruns it and every member check updates.

Factored load effects for the mezzanine beam, the edge girder and the roof truss chords.
# Maintenance bay: factored load effects with NBC load combinations (kN, m)
L_beam, s_beam = 9.0, 3.0          # mezzanine beam span and spacing
D_area, L_area = 3.0, 4.8          # kPa: slab on deck + services; light storage
self_wt = 0.65                     # kN/m, assumed beam self-weight

wD = D_area * s_beam + self_wt
wL = L_area * s_beam
cases = {
    "Case 1: 1.4D":        1.4 * wD,
    "Case 2: 1.25D + 1.5L": 1.25 * wD + 1.5 * wL,
    "Case 2: 0.9D + 1.5L":  0.9 * wD + 1.5 * wL,
}
print(f"wD = {wD:.2f} kN/m, wL = {wL:.2f} kN/m")
for name, w in cases.items():
    print(f"{name:22s} wf = {w:6.2f} kN/m  Mf = {w*L_beam**2/8:6.1f} kN.m  Vf = {w*L_beam/2:6.1f} kN")
wf = max(cases.values())
Vf = wf * L_beam / 2

# Edge girder: beam reactions at the third points of a 9 m span
P = Vf
Mf_girder = P * L_beam / 3
print(f"Girder: P = {P:.1f} kN at third points, Mf (before self-weight) = {Mf_girder:.1f} kN.m")

# Roof truss (CIV-224): 18 m span, 3 m panels, 2.0 m deep, trusses at 7.5 m
wD_r, wS_r = 7.7, 19.7             # kN/m along the truss
wf_r = 1.25 * wD_r + 1.5 * wS_r
P_r = wf_r * 3.0
R = 3 * P_r
M_U2 = R * 6 - P_r / 2 * 6 - P_r * 3
M_L3 = R * 9 - P_r / 2 * 9 - P_r * 6 - P_r * 3
print(f"Truss: wf = {wf_r:.1f} kN/m, panel load P = {P_r:.1f} kN")
print(f"Bottom chord L2L3 tension = {M_U2/2.0:.1f} kN, top chord U2U3 compression = {M_L3/2.0:.1f} kN")
Output
wD = 9.65 kN/m, wL = 14.40 kN/m
Case 1: 1.4D           wf =  13.51 kN/m  Mf =  136.8 kN.m  Vf =   60.8 kN
Case 2: 1.25D + 1.5L   wf =  33.66 kN/m  Mf =  340.8 kN.m  Vf =  151.5 kN
Case 2: 0.9D + 1.5L    wf =  30.28 kN/m  Mf =  306.6 kN.m  Vf =  136.3 kN
Girder: P = 151.5 kN at third points, Mf (before self-weight) = 454.4 kN.m
Truss: wf = 39.2 kN/m, panel load P = 117.5 kN
Bottom chord L2L3 tension = 705.1 kN, top chord U2U3 compression = 793.3 kN

Ultimate and serviceability limit states in steel

Each member type has its own list of limit states, and the design checks all that apply. The table shows the ones covered in this course and where.

Limit states for steel members and connections.
MemberMain limit statesLesson
Tension memberYielding of gross section, fracture of net section, block shear3
ColumnFlexural, torsional and local buckling4
BeamPlastic moment, local buckling, lateral-torsional buckling, shear, web crippling, deflection5 to 7
Beam-columnInteraction of axial load and bending, with second-order effects8 and 11
Bolted jointBolt shear, bearing and tearout, slip, block shear9
Welded jointWeld metal shear, base metal shear10
FrameSway stability, bracing strength and stiffness, drift11

Serviceability limit states use specified loads. Common deflection limits are span/360 under live load for floors with brittle finishes and span/240 under total load, but they are guidance in the NBC commentary rather than code requirements, and crane runways and monorails need stricter limits. Floor vibration matters more as steel floors become lighter; the CISC and AISC publish design guides for walking vibration.

Who does what

A steel building passes through many hands. The structural engineer of record designs the members and states the connection forces on the design drawings. In Canada it is common for the connections themselves to be designed by an engineer retained by the fabricator, working from those forces. A detailer prepares shop drawings showing every piece, hole and weld; the engineer of record reviews them for conformance with the design. The fabricator buys steel with mill test certificates, cuts, drills and welds it in a shop certified to CSA W47.1, and the erector assembles the frame. Inspection and testing agencies check bolting and welding. When you design a member, you are also writing instructions for all of these people, so clear drawings and complete connection forces matter as much as correct calculations.

A good steel design is also an economical one. The cost of a steel frame depends more on the number of pieces and connections than on the weight of steel. Repeating the same beam size across a floor, choosing connections the local fabricators prefer, and avoiding stiffeners and complex welds often save more than shaving the weight of each member.

Common mistakes

  • MistakeMixing factored and specified loads in the same check.

    InsteadStrength checks use factored loads; deflection and vibration checks use specified loads.

  • MistakeUsing 1.25D + 1.5L for a roof without checking the snow case.

    InsteadRoof members are often governed by case 3, with snow as the principal load.

  • MistakeTreating a simple connection as rigid in the analysis, or the reverse.

    InsteadThe analysis model must match the connections that will be built.

  • MistakeChoosing the lightest section for every member.

    InsteadFewer sizes and simpler connections often cost less than a small saving in weight.

Summary and key terms

  • Steel is strong, light and ductile, but slender members buckle and the material needs protection from fire, corrosion, fatigue and brittle fracture.
  • Buildings combine beams, girders, columns, trusses, joists and deck; braced frames or moment frames resist lateral load.
  • S16 requires the factored resistance \(\phi R\) to be at least the effect of the factored loads from the NBC load cases.
  • Resistance factors are high for ductile yielding and lower for fracture, bolts and welds.
  • The mezzanine beam carries \(M_f = 341\) kN·m and \(V_f = 152\) kN; the truss bottom chord carries 705 kN in tension.
Limit state
A condition beyond which a structure or member no longer meets a design requirement.
Factored resistance
The nominal resistance multiplied by the resistance factor φ.
Resistance factor
A factor less than 1.0 applied to a nominal resistance to account for variability and the consequences of failure.
Load factor
A factor applied to a specified load to account for loads larger than expected.
Braced frame
A frame that resists lateral load through diagonal members acting as a vertical truss.
Moment frame
A frame that resists lateral load through rigid beam-to-column connections.
Simple connection
A connection that transfers shear but allows the beam end to rotate.
Shop drawings
Drawings prepared for the fabricator that show every piece, hole and weld.

Practice problems

Work each problem on paper first, then reveal the answer to check.

  1. A roof beam spanning 7.5 m at 2.5 m centres carries 1.2 kPa dead and 2.6 kPa snow. Find \(M_f\).

    Show answer

    \(w_f = 1.25(3.0) + 1.5(6.5) = 13.5\) kN/m; \(M_f = 13.5(7.5)^2/8 = 95\) kN·m.

  2. Why is \(\phi_u\) lower than \(\phi\)?

    Show answer

    Fracture of a net section is less predictable and gives no warning, so it needs a larger margin than yielding.

  3. Name two serviceability limit states for a steel floor.

    Show answer

    Deflection under live load and walking vibration.

  4. Why might a braced frame be chosen over a moment frame?

    Show answer

    Bracing uses less steel and allows simple, cheap connections; moment frames are chosen where open bays are needed.