MCAT-110 · Lesson 4 of 12 · 21 min

Lab techniques: separating and identifying biomolecules

▶ Video coming soon A video version of this lesson is on the way.

Thandiwe had taught undergraduate biochemistry labs for six years before she started coaching, and she opened this session with a confession of her own. 'Every year, the students who did best on my lab exams were not the ones with the best hands. They were the ones who could say, for each step, what property of the molecule it was using.' She put up a list: size, charge, shape, solubility, binding partners. 'Every separation method on the MCAT uses one of these. If you can name the property, you can answer the question.'

Passages about experiments make up much of the science sections, and many of them describe how a protein or nucleic acid was purified, separated or detected. The AAMC outline lists separation and purification methods in content category 5C, and the analysis of proteins under category 1A; the skills of reasoning about research design and reading data, skills 3 and 4, are tested through them. This lesson covers breaking cells and fractionating them, chromatography, electrophoresis, detection and quantification, and methods for identifying proteins and determining their structure.

Getting the molecule out of the cell

Purification starts by breaking cells open, a step called lysis, using detergents, sound waves, pressure or grinding. The result is a crude mixture of everything the cell contained. Centrifugation then separates components by size and density. In differential centrifugation, the mixture is spun at increasing speeds: nuclei and unbroken cells settle at low speed, mitochondria at moderate speed, smaller membrane fragments and ribosomes at high speed, and soluble proteins remain in the supernatant. Density-gradient centrifugation separates particles in a column of sucrose or cesium chloride whose density increases toward the bottom; each particle settles where its density matches the medium.

Proteins can also be separated by solubility. Adding a high concentration of a salt such as ammonium sulfate makes proteins less soluble, because the salt ions compete for water; different proteins precipitate at different salt concentrations, a process called salting out. The excess salt is later removed by dialysis, in which the sample sits in a bag of semipermeable membrane in a large volume of buffer: small molecules pass out through the membrane's pores, and large proteins stay inside.

Chromatography

Chromatography separates molecules by how strongly they interact with a stationary phase, a solid or gel packed into a column or spread on a plate, as a mobile phase flows past. Molecules that interact weakly with the stationary phase move quickly; those that interact strongly move slowly or stick until the conditions change.

Common chromatography methods and the properties they use.
MethodProperty usedWhat comes off the column firstHow bound molecules are released
Size-exclusion (gel filtration)SizeLarge molecules, which cannot enter the pores of the beadsNothing binds; molecules simply flow through at different speeds
Ion exchangeChargeMolecules with the same charge as the beads, or no chargeRaising the salt concentration or changing the pH
AffinitySpecific binding to a ligand, antibody or tagEverything except the targetAdding excess free ligand or changing conditions; for example, imidazole releases histidine-tagged proteins from nickel beads
Hydrophobic interactionExposed nonpolar surfaceThe most hydrophilic proteinsLowering the salt concentration
Thin-layer and paper chromatographyPolarity relative to a polar plateNonpolar compounds travel farthest on a polar plateNot applicable; spots are compared by Rf, distance traveled divided by solvent distance

Size-exclusion chromatography confuses many students because it seems backward. The beads are porous. Small molecules enter the pores and take a long, winding path through the column; large molecules are excluded from the pores and pass straight through. So the largest molecules come out first.

In ion-exchange chromatography, the beads carry a charge. A cation exchanger has negative beads and binds positively charged proteins; an anion exchanger has positive beads and binds negatively charged proteins. Whether a protein is positive or negative depends on the buffer pH relative to its isoelectric point, which ties this method to lesson 1. Below its pI, a protein is positive and binds a cation exchanger; above its pI, it is negative and binds an anion exchanger. Bound proteins are released, or eluted, by increasing salt, whose ions compete for the charged sites.

Affinity chromatography is the most selective method, often purifying a protein in one step. Researchers commonly add a short tag of six histidines to a protein's gene; the tagged protein binds tightly to beads carrying nickel ions and is released with imidazole, which resembles the histidine side chain. High-performance liquid chromatography, or HPLC, uses the same principles with fine particles and high pressure for faster, sharper separations.

Electrophoresis

Electrophoresis moves charged molecules through a gel in an electric field. Negatively charged molecules move toward the positive electrode, the anode; positively charged molecules move toward the negative electrode, the cathode. The gel acts as a sieve, so smaller molecules move faster.

Types of gel electrophoresis.
MethodSeparates byKey features
Native polyacrylamide gel electrophoresis (PAGE)Charge, size and shape togetherThe protein stays folded and can remain active
SDS-PAGEMass (length of the chain)Sodium dodecyl sulfate denatures proteins and coats them with negative charge roughly in proportion to length; a reducing agent breaks disulfides, so subunits separate
Isoelectric focusingIsoelectric pointA gel with a pH gradient; each protein moves until it reaches the pH equal to its pI, where its net charge is zero, and stops
Two-dimensional electrophoresispI in one direction, then mass in the otherResolves thousands of proteins as separate spots
Agarose gel electrophoresisSize of DNA or RNA fragmentsNucleic acids are negative because of their phosphate backbone and move toward the anode; smaller fragments move farther
A drawing of an SDS-PAGE gel with four lanes. The negative electrode is at the top and the positive electrode at the bottom. Lane 1 is a ladder of marker bands labeled 100, 75, 50, 37, 25 and 15 kilodaltons from top to bottom. Lane 2, a protein under nonreducing conditions, shows one band near 100. Lane 3, the same protein with a reducing agent, shows two bands near 50 and 25. Lane 4 shows a purified sample with one band near 37.
Reading an SDS-PAGE gel. Smaller proteins run farther. A protein that gives one band without reducing agent and two with it contains subunits joined by disulfide bonds. Schematic.

SDS-PAGE gels are the most common in passages. Because SDS gives every protein a similar charge-to-mass ratio, migration depends almost entirely on mass, and a protein's mass is estimated by comparing its band with a ladder of markers of known mass. Comparing samples run with and without a reducing agent reveals disulfide-linked subunits: a 100-kilodalton band that becomes bands at 50 and 25 kilodaltons when reduced suggests subunits held together by disulfide bonds, for example two 25-kilodalton chains and one 50-kilodalton chain. In native PAGE, by contrast, a multimeric protein runs as one complex.

Detecting and measuring molecules

Once separated, molecules must be detected and measured. Proteins absorb ultraviolet light at 280 nanometers, mostly because of tryptophan and tyrosine side chains, and nucleic acids absorb strongly at 260 nanometers because of their bases. The ratio of absorbance at 260 to 280 is a common check of nucleic acid purity. Color-based assays, such as the Bradford assay, in which a dye changes color when it binds protein, measure protein concentration against a standard curve.

All these absorbance methods rely on the Beer-Lambert law: absorbance equals the molar absorptivity times the path length times the concentration. Absorbance is proportional to concentration, so doubling the concentration doubles the absorbance, as long as readings stay within the linear range of the instrument. Questions often give a standard curve and ask you to read an unknown concentration from it.

Enzyme purifications are tracked with a purification table. Total activity measures how much enzyme is present in a fraction; specific activity, the activity per milligram of total protein, measures purity. As purification proceeds, total protein falls sharply, total activity falls a little at each step because some enzyme is lost, and specific activity rises. The fold purification is the specific activity at a step divided by the specific activity of the crude extract, and the yield is the total activity remaining as a share of the starting activity.

Worked problem

Reading a purification table

A crude extract contains 2,000 milligrams of protein and 4,000 units of enzyme activity. After affinity chromatography, the fraction contains 5 milligrams of protein and 2,400 units. Calculate the specific activity at each step, the fold purification and the yield.

Show solution
  1. Crude specific activity: 4,000 units divided by 2,000 milligrams equals 2 units per milligram.
  2. After affinity chromatography: 2,400 divided by 5 equals 480 units per milligram.
  3. Fold purification: 480 divided by 2 equals 240-fold.
  4. Yield: 2,400 divided by 4,000 equals 0.6, or 60 percent of the starting activity.

Answer: Specific activity rose from 2 to 480 units per milligram, a 240-fold purification, with a 60 percent yield. A good step raises specific activity a lot while keeping most of the activity.

Identifying proteins and determining structure

Antibodies provide specific detection. In a western blot, proteins are separated by SDS-PAGE, transferred to a membrane and probed with an antibody against the target protein; a second, labeled antibody that binds the first produces a visible band, showing whether the protein is present and its approximate size. In an ELISA, an enzyme-linked immunosorbent assay, an antigen or antibody is fixed to a plate and detected by an antibody linked to an enzyme that produces a colored product, allowing concentrations to be measured in many samples at once.

Mass spectrometry measures the mass-to-charge ratio of ionized molecules and can identify a protein from the masses of its fragments, detect modifications such as phosphorylation, and measure the amounts of many proteins in a sample. Edman degradation, an older method, removes and identifies one amino acid at a time from the N-terminus. Treating a protein with proteases or chemicals that cut at specific residues produces predictable fragments: trypsin cuts after lysine and arginine, and chymotrypsin after large aromatic residues.

Three methods reveal three-dimensional structure. X-ray crystallography measures how a protein crystal diffracts X-rays and can give a detailed atomic model, but the protein must first be crystallized. Nuclear magnetic resonance spectroscopy determines the structure of proteins in solution, usually smaller ones, and shows how they move. Cryo-electron microscopy images many frozen copies of a molecule and averages them; it is well suited to large complexes and membrane proteins that are hard to crystallize.

Matching methods to questions, a common style of research-design question.
Question the researcher asksA good method
How large is this protein, and does it have disulfide-linked subunits?SDS-PAGE with and without a reducing agent
Is the protein present in this tissue sample?Western blot
How much of a hormone is in each of 90 blood samples?ELISA
What is the protein's isoelectric point?Isoelectric focusing
Is this residue phosphorylated?Mass spectrometry
What does the active site look like with an inhibitor bound?X-ray crystallography or cryo-electron microscopy
Which large and small proteins are in this mixture, without denaturing them?Size-exclusion chromatography

Passage-style practice

Passage. A research team purified an enzyme, enzyme T, from yeast in four steps and tracked total protein and activity. They then analyzed the final fraction by SDS-PAGE. Without a reducing agent, the fraction gave a single band at about 120 kilodaltons; with a reducing agent, it gave a single band at about 60 kilodaltons. On size-exclusion chromatography under native conditions, the enzyme eluted at a volume corresponding to about 240 kilodaltons. Data invented for this course.

Purification of enzyme T. Data invented for this course.
StepTotal protein (milligrams)Total activity (units)Specific activity (units per milligram)
1: crude extract3,0006,0002
2: ammonium sulfate cut9005,4006
3: ion exchange604,20070
4: size exclusion123,000250

Practice problems

Work each problem on paper first, then reveal the answer to check.

  1. What is the fold purification after step 4? (Skill 4: data-based reasoning)

    Show answer

    250 divided by 2 equals 125-fold.

  2. What is the overall yield? (Skill 4)

    Show answer

    3,000 divided by 6,000 equals 50 percent.

  3. Which step gave the largest increase in purity? (Skill 4)

    Show answer

    Step 3, ion exchange, which raised specific activity from 6 to 70 units per milligram, nearly twelvefold.

  4. What do the SDS-PAGE and size-exclusion results together suggest about the enzyme's quaternary structure? (Skill 2: scientific reasoning)

    Show answer

    Identical 60-kilodalton subunits form disulfide-linked pairs of 120 kilodaltons, and two such pairs associate noncovalently into a native complex of about 240 kilodaltons, a tetramer.

  5. At step 3, the buffer was pH 8 and the enzyme bound to an anion exchanger. What does that suggest about its pI? (Skill 2)

    Show answer

    The enzyme was negatively charged at pH 8, so its pI is below 8.

Controls in experimental passages

Research-design questions often ask which control an experiment needs, and lab-technique passages are where they appear most. A negative control shows what the result looks like when the thing being tested is absent: a lane loaded with buffer alone, an assay run without enzyme, or a western blot of cells that lack the protein. A positive control shows that the method works: a purified sample of the protein on the same blot, or a substrate known to react. A loading control checks that equal amounts of material were compared; on western blots, researchers often probe for a protein expected to be equally abundant in every sample. Thandiwe asked the group to look at every passage table with one question in mind: if this result surprised me, which row would tell me whether the method failed or the hypothesis did? That question usually points straight to the control the answer choices are testing.

Common mistakes

  • MistakeIn size-exclusion chromatography, small molecules come out first.

    InsteadLarge molecules are excluded from the pores and elute first; small ones take longer paths.

  • MistakeSDS-PAGE separates proteins by charge.

    InsteadSDS gives proteins similar charge-to-mass ratios, so they separate mainly by mass.

  • MistakeIn isoelectric focusing, a protein moves to the end of the gel.

    InsteadIt stops at the pH equal to its pI, where its net charge is zero.

  • MistakeSpecific activity measures how much enzyme is present.

    InsteadTotal activity measures amount; specific activity, activity per milligram of protein, measures purity.

  • MistakeDNA in an agarose gel moves toward the negative electrode.

    InsteadDNA is negatively charged and moves toward the positive anode.

Summary and key terms

  • Every separation uses a physical property: size, density, charge, solubility, polarity or specific binding.
  • Centrifugation separates by size and density; salting out by solubility; dialysis removes small molecules.
  • Size-exclusion chromatography elutes large molecules first; ion exchange separates by charge relative to pI; affinity chromatography uses specific binding.
  • SDS-PAGE separates by mass, isoelectric focusing by pI, and agarose gels separate nucleic acids by size.
  • Absorbance at 280 and 260 nanometers measures protein and nucleic acid, following the Beer-Lambert law.
  • Purification tables track total activity, specific activity, fold purification and yield.
  • Western blots, ELISA, mass spectrometry, crystallography, NMR and cryo-electron microscopy identify proteins and reveal structure.
Dialysis
Removal of small molecules from a sample through a semipermeable membrane.
Size-exclusion chromatography
Separation by size in a column of porous beads; the largest molecules elute first.
Ion-exchange chromatography
Separation by charge on charged beads, with elution by salt or pH.
SDS-PAGE
Gel electrophoresis of denatured, SDS-coated proteins, separating them by mass.
Isoelectric focusing
Electrophoresis in a pH gradient that separates proteins by isoelectric point.
Specific activity
Enzyme activity per milligram of total protein, a measure of purity.
Western blot
Detection of a specific protein on a membrane with antibodies after electrophoresis.

Lesson quiz · 5 questions

Score 60% or more to complete this lesson.

Take the quiz