CIV-341 · Lesson 1 of 12 · 22 min
The foundation design process and limit states
Soil mechanics, the subject of CIV-340, explains how soil carries stress, how water moves through it and how it compresses and fails. Foundation engineering puts that knowledge to work. Its question is practical: what should the structure stand on, how big must it be, how deep must it go, and how will it behave over the life of the building? This course answers that question for the buildings of the Kestrel Bay operations centre in Thunder Bay, from the spread footings of the garage designed in CIV-330 to the piles that will carry a new fleet storage building, and finishes with a complete foundation design package. This first lesson sets out the design process, the people involved and the limit states framework that every later calculation will use.
What a foundation must do
A foundation transfers the loads of a structure into the ground. To do that successfully it has to satisfy three requirements at the same time. First, the ground must not fail: the soil beneath and around the foundation must not shear, punch or slide under the loads, with an adequate margin for uncertainty. Second, the foundation must not move too much: total settlement, differential settlement between parts of the structure, tilt and lateral movement must stay within what the structure, its finishes and its services can tolerate. Third, the foundation itself must be strong and durable: the concrete, steel or timber in it must carry the forces it receives, resist frost, sulphates, corrosion and abrasion, and be buildable with the equipment and methods available on the site.
A fourth requirement is often forgotten until it causes trouble: the foundation must not harm its neighbours. Excavations undermine adjacent footings, dewatering consolidates clays under nearby buildings, pile driving shakes sensitive equipment and heaves the ground, and new loads drag down existing piles. A good foundation design considers the effect of the work on everything around it, as well as the effect of the ground on the new structure.
The design process
Foundation design is iterative. It begins long before the structural drawings are finished and continues until the last pile is accepted in the field. The main stages are these.
- Desk study. Before drilling a single hole, the geotechnical engineer reads the geological maps, previous investigations on or near the site, air photos and records of fill or old structures. At Kestrel Bay the desk study showed glacial lake clays over till, with a known artesian aquifer in the till near the lake.
- Site investigation. Boreholes, sampling, in-situ tests such as the SPT, CPT and field vane, groundwater measurements and laboratory tests establish the ground model. Lesson 2 reviews how to plan and interpret an investigation for foundation design.
- Ground model and design parameters. The engineer turns the factual data into a model: the layers, their thicknesses, the groundwater conditions and characteristic values of strength, stiffness and compressibility for each layer.
- Selection of the foundation type. Shallow foundations (spread footings, strip footings, combined footings and mats) are considered first, because they are usually the cheapest. Deep foundations (driven piles, drilled shafts, helical piles and micropiles) are used when shallow foundations would fail, settle too much or be impractical.
- Design calculations. Bearing resistance, settlement, sliding, uplift, lateral resistance and the structural design of the foundation elements are checked for all relevant load cases.
- Interaction with the structural engineer. The geotechnical engineer gives bearing resistances, settlement predictions and spring stiffnesses; the structural engineer gives loads and tolerances. The loads change as the structure develops, and the foundation design changes with them.
- Construction and verification. Field inspection confirms that the ground matches the model: the founding soil is what was expected, the piles reach the required set or depth, and load tests confirm the predicted resistance. Monitoring of settlement and pore pressures may continue for years.
Who does what
On a building project in Ontario, the structural engineer of record designs the foundation elements as structural members, while the geotechnical engineer, a licensed professional engineer with expertise in soils, provides the geotechnical design: the bearing resistances, the settlement predictions, the pile resistances and the construction recommendations. The responsibilities are set out in the contracts and, for larger buildings, in the general review commitments required by the building code. Dr. Lena Kowalczyk, P.Eng., the geotechnical engineer who wrote the soils report in CIV-340, now leads the foundation design for Kestrel Bay Engineering, with Owen Lachance, EIT, doing the calculations and Sofia Martel, a co-op student, writing the Python scripts that check them.
Uncertainty in geotechnical design
Structural engineers work with materials whose properties are specified, manufactured and tested: a steel grade has a guaranteed minimum yield strength, and concrete is tested in cylinders from every pour. Geotechnical engineers work with materials that nature made. The soil under a footing was deposited thousands of years ago and has been sampled at a few points, perhaps a few litres of soil for a site of thousands of cubic metres. Its properties vary from place to place, and the methods used to calculate bearing resistance and settlement are themselves approximate.
That uncertainty is the reason for safety margins. It is also why geotechnical design relies so heavily on judgement, experience and observation. Karl Terzaghi, who founded soil mechanics in the 1920s, and Ralph Peck, his colleague, insisted that calculations be checked against field behaviour, and Peck's observational method, in which a design is adapted during construction according to what monitoring reveals, remains an important tool when the ground is too uncertain to design with confidence in advance.
Limit states
A limit state is a condition beyond which the foundation no longer fulfils its purpose. Modern codes group limit states into two families.
Ultimate limit states (ULS) involve collapse or failure: bearing failure of the ground, sliding, overturning, uplift of a buoyant structure, failure of a pile in compression or tension, or structural failure of a footing or pile. For these, the design must give a high level of safety, because failure could cost lives.
Serviceability limit states (SLS) involve loss of function without collapse: excessive total or differential settlement, tilt, vibration or lateral movement. They are checked with unfactored, specified loads, because they concern the everyday behaviour of the structure. In most foundation designs on soil, serviceability rather than bearing failure governs the size of the foundation.
In Canada, the National Building Code (NBC) uses limit states design for foundations, consistent with the structural parts of the code. The requirement at the ultimate limit state is that the factored geotechnical resistance be at least equal to the effect of the factored loads:
where \(R_u\) is the ultimate geotechnical resistance computed with characteristic (best estimate, somewhat conservative) parameters, \(\phi_{gu}\) is the geotechnical resistance factor and \(\alpha_i S_i\) are the factored load effects from the NBC load combinations, such as \(1.25D + 1.5L\). The geotechnical resistance factors account for the uncertainty in the ground and in the method of calculation. Values in Canadian practice, given in the NBC and the Canadian Foundation Engineering Manual (CFEM, 5th edition, 2023), are typically about 0.5 for the bearing resistance of shallow foundations calculated by analysis, about 0.8 for sliding on a frictional soil, about 0.4 for the compression resistance of piles calculated by static analysis and about 0.6 when the resistance is confirmed by a static load test. The CFEM also introduces a consequence factor that adjusts the target safety according to the importance of the structure and the understanding of the site. At the serviceability limit state, a serviceability resistance factor, typically around 0.8, may be applied to the pressure that causes the tolerable settlement.
Why factors of safety are large
A factor of safety of 3 on bearing capacity seems generous compared with the factors of about 1.5 implied in structural steel design. It is not. The bearing capacity theory of lesson 3 is sensitive to the friction angle: a change of two degrees changes the bearing capacity of a footing on sand by about 30 %. The friction angle itself is usually estimated from SPT or CPT correlations with a scatter of several degrees. The large factor covers the uncertainty in the parameters, the approximations in the theory and the fact that the bearing pressure that causes failure is usually accompanied by settlements far larger than any structure could tolerate. A factor of 3 on bearing also tends to keep settlements of footings on sand within acceptable limits, which is one reason it has survived so long in practice.
The limit states format does not remove the need for judgement. A resistance factor of 0.5 applied with the NBC load factors gives an equivalent global factor of safety of about 2.5 to 2.8, depending on the ratio of live to dead load. That is somewhat lower than the traditional value of 3, and the difference is deliberate: the load factors carry part of the uncertainty that used to be lumped into the single factor of safety.
The garage footing as a first example
CIV-330 designed the interior footings of the garage as 3.0 m squares founded 2.0 m below grade, for column loads of \(D = 1700\) kN and \(L = 720\) kN. The structural design used a serviceability bearing pressure of 280 kPa given in a preliminary report. The soils report of CIV-340 then found a sand layer only 2.0 m thick below the footings, over a soft to firm clay. Dr. Kowalczyk asks Owen to start the foundation design from the beginning: what bearing resistance does the footing need, and does the ground provide it?
Worked problem
Required bearing resistance of the interior footing
The 3.0 m square footing weighs 159 kN and carries 203 kN of backfill. Find the factored and specified gross bearing pressures, and the ultimate bearing resistance needed with \(\phi_{gu} = 0.5\).
Show solution
- Total dead load, including the footing and the backfill:
- \[D = 1700 + 159 + 203 = 2062\ \text{kN}\]
- Factored load and pressure:
- \[P_f = 1.25(2062) + 1.5(720) = 3658\ \text{kN} \qquad q_f = \frac{3658}{9.0} = 406\ \text{kPa}\]
- Required ultimate bearing resistance:
- \[q_u \ge \frac{q_f}{\phi_{gu}} = \frac{406}{0.5} = 813\ \text{kPa}\]
- Specified load for serviceability: \(D + L = 2782\) kN, a gross pressure of 309 kPa.
Answer: The ground must provide an ultimate bearing resistance of at least 813 kPa. Lessons 3 and 4 will show that the sand alone could provide far more, but the clay beneath it reduces the resistance to about 1,100 kPa, still adequate.
Sofia's script repeats the calculation and tabulates the equivalent global factor of safety of the factored format for different ratios of live to dead load.
# Limit states check of the interior garage footing (NBC loads, CFEM-style resistance factor)
D_col, L_col = 1700.0, 720.0 # specified column loads (kN)
W_ftg, W_fill = 159.0, 203.0 # footing and backfill over it (kN)
B, phi_gu = 3.0, 0.5 # footing width (m), geotechnical resistance factor for bearing
A = B * B
D = D_col + W_ftg + W_fill
Pf = 1.25 * D + 1.5 * L_col # governing ULS combination
Ps = D + L_col # SLS (specified) load
print(f"Dead load incl. footing and fill D = {D:.0f} kN, live L = {L_col:.0f} kN")
print(f"ULS factored load Pf = 1.25D + 1.5L = {Pf:.0f} kN -> qf = {Pf/A:.0f} kPa")
print(f"SLS specified load Ps = D + L = {Ps:.0f} kN -> qs = {Ps/A:.0f} kPa")
print(f"Required ultimate bearing resistance: qu >= qf / phi = {Pf/A/phi_gu:.0f} kPa")
print(f"For comparison, working stress with FS = 3: qu >= 3 qs = {3*Ps/A:.0f} kPa")
print("\nEquivalent global factor of safety of the limit states format")
print(" L/D FS = (1.25 + 1.5 L/D) / (phi (1 + L/D))")
for r in (0.0, 0.25, 0.42, 0.75, 1.0, 1.5):
fs = (1.25 + 1.5 * r) / (phi_gu * (1 + r))
print(f"{r:4.2f} {fs:5.2f}")Dead load incl. footing and fill D = 2062 kN, live L = 720 kN ULS factored load Pf = 1.25D + 1.5L = 3658 kN -> qf = 406 kPa SLS specified load Ps = D + L = 2782 kN -> qs = 309 kPa Required ultimate bearing resistance: qu >= qf / phi = 813 kPa For comparison, working stress with FS = 3: qu >= 3 qs = 927 kPa Equivalent global factor of safety of the limit states format L/D FS = (1.25 + 1.5 L/D) / (phi (1 + L/D)) 0.00 2.50 0.25 2.60 0.42 2.65 0.75 2.71 1.00 2.75 1.50 2.80
Reading the results
The equivalent factor of safety rises from 2.50 for a pure dead load to 2.80 for a live load one and a half times the dead load. For the garage footing, with \(L/D = 0.35\) once the footing and backfill weights are included, it is about 2.6. The working stress approach with a factor of 3 would demand an ultimate resistance of 927 kPa instead of 813 kPa. Neither is right or wrong; they are two calibrations of the same idea. What matters is that the engineer uses one format consistently, with the load factors and resistance factors that belong together.
Serviceability criteria
For the serviceability limit state, the engineer needs to know what movement the structure can tolerate. That depends on the structure. A steel portal-frame warehouse with metal cladding can accept differential settlements that would crack the brick walls of an office building. Lesson 6 gives the widely used criteria for angular distortion and total settlement. At this stage, Owen notes the targets agreed with the structural engineer for the garage: total settlement of footings not more than about 50 mm, and angular distortion between adjacent columns not more than 1/500, because the garage has a concrete flat plate and masonry partitions.
Serviceability also includes things other than settlement: the heave of footings on frost-susceptible soil, the swelling of expansive clays, vibrations from machinery and the movement of a basement wall. Many foundation failures in practice are serviceability failures caused by water: poor drainage, a broken pipe, or a change in the water table that the design did not anticipate.
Practical points
- Start every foundation design with the ground model and the loads; check that both are current.
- Check ultimate limit states with factored loads and factored resistances, or with service loads and a factor of safety, but never mix the two formats.
- Check serviceability with unfactored, specified loads, and agree the tolerable movements with the structural engineer.
- Include the weight of the footing and the backfill in the loads when working with gross pressures.
- Consider the effect of the construction on neighbouring structures as well as the effect of the ground on the new structure.
Common mistakes
MistakeApplying a factor of safety of 3 to a resistance already multiplied by a resistance factor.
InsteadUse one format: a resistance factor with factored loads, or a factor of safety with service loads.
MistakeSizing a footing for bearing only.
InsteadCheck settlement too; on most soils serviceability governs.
MistakeTreating the soils report values as exact.
InsteadThey are estimates from a few samples; consider their uncertainty and verify during construction.
MistakeForgetting the footing and backfill weights when comparing gross pressures.
InsteadAdd them to the dead load, or work consistently with net pressures.
Summary and key terms
- A foundation must not fail, must not move too much, must be structurally adequate and durable, and must not harm its neighbours.
- Design is iterative: desk study, investigation, ground model, choice of type, calculations, interaction with the structure, construction verification.
- NBC limit states design requires \(\phi_{gu} R_u \ge \sum \alpha_i S_i\); typical \(\phi_{gu}\) is 0.5 for bearing by analysis and 0.4 for piles by static analysis.
- Serviceability limit states, checked with unfactored loads, usually govern the size of shallow foundations.
- The garage footing needs an ultimate bearing resistance of at least 813 kPa.
- Limit state
- A condition beyond which a structure or foundation no longer fulfils its design purpose.
- Ultimate limit state
- A limit state involving collapse or failure, such as bearing failure or sliding.
- Serviceability limit state
- A limit state involving loss of function, such as excessive settlement or tilt.
- Geotechnical resistance factor
- A factor less than one applied to the ultimate geotechnical resistance to account for uncertainty.
- Factor of safety
- The ratio of ultimate capacity to the applied service load in allowable stress design.
- Ground model
- The engineer's interpretation of the layers, groundwater and properties beneath a site.
- Observational method
- A design approach in which the design is adapted during construction according to monitored behaviour.
- Consequence factor
- A factor that adjusts the target reliability of a geotechnical design according to the consequences of failure.
Practice problems
Work each problem on paper first, then reveal the answer to check.
A footing carries \(D = 800\) kN and \(L = 400\) kN, including its own weight. Find the factored load and the ultimate bearing resistance needed on a 2.0 m square footing with \(\phi_{gu} = 0.5\).
Show answer
\(P_f = 1000 + 600 = 1600\) kN; \(q_f = 400\) kPa; \(q_u \ge 800\) kPa.
Why does the equivalent global factor of safety of the factored format increase with the ratio of live to dead load?
Show answer
The live load factor is larger than the dead load factor, so a larger share of live load raises the average load factor.
Give two examples of serviceability limit states for foundations other than settlement.
Show answer
Frost heave, swelling of expansive clay, tilt, lateral movement of walls or vibration of machine foundations.
What is the observational method, and when is it useful?
Show answer
Designing for the most probable conditions with planned changes triggered by monitoring; useful when the ground is too uncertain to design for the worst case economically.
Lesson quiz · 5 questions
Score 60% or more to complete this lesson.
Create a free account to save your progress, take quizzes and earn a certificate.