HSE-374 · Lesson 9 of 12 · 20 min

Fall protection for ironworkers

In the trailer at the Prairie Gate Community Centre, Owen Hartley kept a photograph on the wall from a job twenty years earlier: three ironworkers sitting on a beam high above a city street, eating lunch, with nothing attached to them. Visitors usually smiled at it. Owen used it to start every fall protection talk. 'That picture is famous because they got away with it,' he would say. 'Nobody takes pictures of the ones who didn't.' Falls are the leading cause of death in steel erection, and almost every one of them happens to a worker who was not tied off, was tied off to something that failed, or fell further than the system allowed.

This lesson covers the rules for fall protection in erection work, the order in which protection is chosen, anchorages and lifelines, fall clearance, equipment for connectors and deckers, custody of fall protection left for other trades, and rescue.

The rules

In Manitoba, Part 14 of the regulation applies to steel erection like any other work. Where a worker could fall 3 m (10 ft) or more, or could fall into machinery, water or onto a hazard from any height, the employer must provide fall protection, and a written fall protection plan is needed for work where the regulation requires one. Manitoba's regulation has no separate rule for connectors: the 3 m requirement in Part 14 applies to them like everyone else, so on Tallgrass jobs connectors are tied off or otherwise protected above 3 m. Manitoba's regulation has no controlled decking zone, so decking crews on Tallgrass jobs work tied off or behind guardrails or nets above 3 m. Tallgrass's site rule at the Prairie Gate Community Centre was simple to remember: anyone above 3 m (10 ft) on the frame is protected at all times, including while moving from one place to another.

Fall protection thresholds for erection work at the Prairie Gate Community Centre.
WorkerManitoba (Part 14 and Tallgrass rule)OSHA Subpart R minimum, for comparison
Most workers on steelProtected at 3 m (10 ft) or moreProtected above 15 ft (4.6 m)
ConnectorsProtected at 3 m (10 ft) or more, no separate ruleEquipment worn and ready between 15 and 30 ft or two stories; fully protected above that
Leading-edge deckersProtected at 3 m (10 ft) or more, no controlled decking zoneMay work in a CDZ between 15 and 30 ft under strict limits
Other trades after the erectorProtected at 3 m (10 ft) or moreSubpart M rules for their own work

Choosing the protection

Fall protection is chosen in an order of preference, from methods that remove the hazard to methods that only reduce the harm.

  • Eliminate the hazard. Do the work on the ground or from a permanent floor. Pre-assembling sections of steel, bracing and lifelines on the ground and lifting them as units, attaching perimeter cable stanchions and ladders to columns before they go up, and connecting from a lift all remove time at height.
  • Guardrails, perimeter cables and covers. Passive protection that works without the worker doing anything.
  • Safety nets. Nets below the work catch falling workers and, with debris nets, falling objects. They need clear space below them and must be installed and tested by competent people.
  • Travel restraint. A harness and lanyard short enough that the worker cannot reach the edge.
  • Fall arrest. A harness, connector and anchorage that stop a fall after it starts. Fall arrest works only if it is attached, if the anchorage holds, and if there is enough clear space below.

On a steel frame, the work happens at edges, so fall arrest is often unavoidable. But the more work moved to the ground, to lifts and behind guardrails, the less depends on a worker clipping on correctly every time.

Anchorages and lifelines

An anchorage must be strong enough to stop a fall. For a single worker using fall arrest, the anchorage must hold a load set by the regulation or standard, typically several times the maximum arrest force, or be designed by an engineer with a safety factor. On a steel frame, common anchorages include the following.

  • The steel itself. A beam with a beam strap or a sliding beam anchor, or a column with a choker strap. The member must be connected well enough to take the load; a beam held by only two wrench-tight bolts may not be a suitable anchorage, so the erection plan says when a member may be used.
  • Horizontal lifelines. Wire rope lines strung between columns, letting workers move along a beam while staying attached. Horizontal lifelines sag under load and put very high forces on their end anchorages, so they must be designed by a qualified person or engineer and installed to the design, with the right tension and energy absorber.
  • Vertical lifelines and self-retracting lifelines (SRLs). For climbing columns and working at the leading edge.
  • Joists and purlins. Only with written approval from a qualified person, because light members can twist or fail under a fall arrest load.

At the Prairie Gate Community Centre, Sanjay Mehta designed the horizontal lifelines on each floor, and the cable stanchions were bolted to the columns on the ground before the columns were lifted. Connectors used twin-leg SRLs so that one leg was always attached as they moved between anchorages.

Fall clearance

Fall arrest only works if the worker stops before hitting the next level or a structural member. The clearance needed below the working surface is the sum of the free fall distance, the deceleration distance of the energy absorber or SRL, harness stretch and D-ring shift, the height of the worker's body below the D-ring, and a safety margin. For a worker tied off at foot level on a beam with a 1.8 m (6 ft) shock-absorbing lanyard, the clearance needed can be more than 5.5 m (18 ft), which is more than one storey.

# Fall clearance for a 1.8 m shock-absorbing lanyard anchored at foot level (illustrative SI values).
lanyard = 1.8            # m
anchor_above_feet = 0.0  # anchored at the beam the worker stands on
d_ring_height = 1.5      # m above the feet
free_fall = lanyard + d_ring_height - anchor_above_feet
decel = 1.07             # maximum deceleration distance for a typical energy absorber, m
stretch = 0.3            # harness stretch and D-ring shift, m
body_below_ring = 1.5    # feet are this far below the D-ring at the end of the fall
margin = 0.6
total = free_fall + decel + stretch + body_below_ring + margin
print(f"free fall: {free_fall:.2f} m")
print(f"clearance needed below the working surface: {total:.2f} m ({total * 3.281:.1f} ft)")
for floor_to_floor in (3.6, 4.0, 4.5):
    print(f"floor-to-floor height {floor_to_floor} m: {'enough' if floor_to_floor >= total else 'NOT enough'}")
Output
free fall: 3.30 m
clearance needed below the working surface: 6.77 m (22.2 ft)
floor-to-floor height 3.6 m: NOT enough
floor-to-floor height 4.0 m: NOT enough
floor-to-floor height 4.5 m: NOT enough

The result is clear: tying off at foot level with a standard lanyard on a single-storey drop does not work. The worker hits the floor below before the lanyard stops them. The answer is to anchor overhead, to a horizontal lifeline or column strap above the D-ring, which cuts the free fall, and to use SRLs rated for the application, which lock within a short distance. SRLs used at a leading edge, where the line can bend over the edge of the deck or steel during a fall, must be rated for leading-edge use.

Two side-by-side elevation sketches. On the left, a worker on a beam is tied off at foot level with a 1.8 m (6 ft) lanyard; arrows add free fall, deceleration, stretch, body height and margin to a total greater than the 4 m (13 ft) storey height, so the worker would strike the floor below, marked with a red cross. On the right, the worker is attached to an overhead horizontal lifeline with a self-retracting lifeline, and the total distance is well within the storey height, marked with a green tick.
Anchoring at foot level with a lanyard can need more clearance than one storey; overhead anchorage with an SRL keeps the fall short.

Equipment for connectors and deckers

Ironworkers need equipment that lets them move and work without disconnecting. At the Prairie Gate Community Centre, each connector wore a full-body harness with a back D-ring and side positioning rings, a twin-leg SRL with leading-edge rating, and a positioning lanyard for hands-free work at a column. Deckers used SRLs connected to the overhead horizontal lifeline. Every harness, lanyard and SRL was inspected by the user before each shift and by a competent person at the intervals the manufacturer requires, and any equipment involved in a fall was removed from service.

Positioning systems hold a worker in place at a column or beam so they can use both hands, but they are not fall arrest. A worker in positioning must also be connected to fall arrest, or the positioning system must limit any fall to a short distance as the regulation allows.

Leaving fall protection for other trades

When the erector finishes a floor and moves on, the perimeter cables, covers and lifelines it installed may be left for the trades that follow. At the Prairie Gate Community Centre, Tallgrass required Northern Iron Erectors Ltd. to hand over each floor's fall protection in writing: Owen inspected the cables and covers with Bill, and once Tallgrass accepted them, Tallgrass became responsible for maintaining them and for keeping other trades informed.

Rescue

A worker hanging in a harness after a fall must be reached quickly. Suspension in a harness can cause suspension trauma, where blood pools in the legs and the worker can lose consciousness. The rescue plan at the Prairie Gate Community Centre used a boom lift kept fuelled and parked near the work, with the key in it and a trained operator on every shift, and a pre-rigged rescue kit for places the lift could not reach. The crew practised a rescue in the first week and again when the gymnasium roof work started. Calling emergency services was part of the plan, not the plan itself.

Worked problem

The lanyard at foot level

Show solution
  1. During a site walk, Owen saw a bolter from a subcontractor sitting on a second-floor beam, tied off with a 1.8 m (6 ft) lanyard wrapped around the beam he was sitting on.
  2. The storey below was 4.0 m (13 ft). With the lanyard anchored at foot level, the clearance needed was more than 5.5 m (18 ft).
  3. Owen asked the bolter to stop and showed him the calculation. If he fell, he would hit the first floor before the lanyard arrested him.
  4. The bolter moved to the horizontal lifeline above the beam with an SRL from the gang box.
  5. Tallgrass added a rule to the site orientation: lanyards are not anchored at or below foot level anywhere on the frame, and all workers at height on steel use overhead anchorages or SRLs.

Answer: Being tied off is not the same as being protected. The system must stop the fall before the worker hits the level below.

Inspecting fall protection equipment

Fall protection equipment fails when it is damaged, worn or used outside its rating. Before each shift, every worker at the Prairie Gate Community Centre checked their harness webbing for cuts, burns, fraying, chemical damage and broken stitching; buckles and D-rings for cracks, distortion and sharp edges; labels for legibility and the date of manufacture; lanyards and energy absorbers for signs that they had been deployed; and SRLs for proper retraction, locking and line condition. A competent person inspected the equipment at least as often as the manufacturer required and recorded the results. Any equipment that had arrested a fall, or failed an inspection, was tagged out and removed from service.

Workers were also trained in how to fit a harness: chest strap across the middle of the chest, leg straps snug enough to fit a flat hand, and the back D-ring between the shoulder blades. A loose harness can let a worker slip out or cause injury in a fall.

Common mistakes

  • MistakeAssuming connectors are exempt from fall protection.

    InsteadManitoba has no connector exemption; protection is required at 3 m (10 ft).

  • MistakeAnchoring a lanyard at foot level on a one-storey drop.

    InsteadCalculate clearance and anchor overhead or use an SRL rated for the job.

  • MistakeUsing a joist as an anchorage because it is close.

    InsteadJoists and purlins are used as anchorages only with written approval from a qualified person.

  • MistakeRigging a horizontal lifeline by hand without a design.

    InsteadHorizontal lifelines must be designed by a qualified person or engineer and installed to the design.

  • MistakeRelying on emergency services for rescue at height.

    InsteadHave equipment and trained people on site to reach a suspended worker within minutes.

Summary and key terms

  • In Manitoba, Part 14 requires fall protection at 3 m (10 ft), with no separate connector or decking-zone rules.
  • Fall protection is chosen in order: eliminate, guardrails and covers, nets, restraint, then fall arrest.
  • Anchorages must be strong enough; horizontal lifelines must be engineered; joists and purlins need qualified approval.
  • Fall clearance includes free fall, deceleration, stretch, body height and margin; anchoring overhead with SRLs keeps falls short.
  • Fall protection left for other trades is handed over in writing, and a practised rescue plan reaches a suspended worker within minutes.
Fall arrest system
A full-body harness, connector and anchorage that stops a fall after it begins.
Travel restraint
A system that stops a worker from reaching an edge where a fall could occur.
Self-retracting lifeline (SRL)
A device with a line that pays out and retracts with the worker and locks quickly if a fall begins.
Horizontal lifeline
A cable or rope strung between anchorages so a worker can move along it while attached.
Fall clearance
The distance needed below a working surface for a fall arrest system to stop a fall safely.
Positioning system
Equipment that holds a worker in place so both hands are free, not a substitute for fall arrest.

Practice problems

Work each problem on paper first, then reveal the answer to check.

  1. At what height does Part 14 require fall protection for workers on a steel frame in Manitoba?

    Show answer

    3 m (10 ft) or more.

  2. List the order of preference for fall protection.

    Show answer

    Eliminate the hazard, guardrails and covers, safety nets, travel restraint, fall arrest.

  3. What makes up fall clearance?

    Show answer

    Free fall, deceleration distance, harness stretch and D-ring shift, body height below the D-ring, and a safety margin.

  4. Why are horizontal lifelines engineered?

    Show answer

    They sag under load and put very high forces on their end anchorages, so the line, tension and anchors must be designed.

  5. What is required before other trades use fall protection installed by the erector?

    Show answer

    The general contractor inspects it and accepts control and responsibility for it in writing.

Lesson quiz · 5 questions

Score 60% or more to complete this lesson.

Take the quiz